Dual-Column Cation-Exchange Chromatographic Method for f3- AminoisobutyricAcid and /3-Alanine in Biological Samples1
نویسندگان
چکیده
A rapid, automated chromatographic method has been developed for the quantitation of the nucleic acid catabolites f3-aminoisobutyric acid and fl-alanine in urine, serum, and other physiological fluids. The analyses were performed on a modified Beckman 121M amino acid analyzer with dual ion-exchange columns and the use of a single sodium citrate buffer (pH 4.38, 0.20 mol/liter). By carefully matching the elution pattern for the two ionexchange columns and alternating use of these columns, analyses are completed every 40 mm. The chromatography, regeneration, and equilibration of the two columns are precisely programmed, thus the detector sees only the elution of fl-aminoisobutyric acid and /3-alanine alternately from each column. Long-term precision and analytical recovery for the two metabolites in urine were 1.9 and 102%, and 3.3 and 101%, respectively. Their normal physiological values were determined in human serum and urine. Their excretion in the urine was also studied as a function of collection time, to validate a more convenient, less costly method of sampling. This study shows that randomly collected samples are acceptable when the concentration of the two metabolites are expressed in terms of creatinine excretion. In addition, the distribution of the free and conjugated forms of the two metabolites in urine and serum was studied. A preparative method was also developed for the quantitative isolation of fl-aminoisobutyric acid from urine samples. The alternating dualcolumn technique may be applied to any ion-exchange chromatographic method where many analyses must be performed. This method is currently used in our laboratories for measuring these fl-amino acids in urine and serum of patients with various types of cancers.
منابع مشابه
Development of a new method based on chiral ligand-exchange chromatography for the enantioseparation of propranolol
A new chromatographic procedure was proposed for the separation of propranolol (PRN) enantiomers based upon enantioselective chiral ligand-exchange chromatography. The separation was carried out on a short C8 column leading to considerably short separation time. L-alanine and Cu2+ were applied as chiral selector and central bivalent complexing ion, respectively. It was found that the kind of co...
متن کاملDevelopment of a new method based on chiral ligand-exchange chromatography for the enantioseparation of propranolol
A new chromatographic procedure was proposed for the separation of propranolol (PRN) enantiomers based upon enantioselective chiral ligand-exchange chromatography. The separation was carried out on a short C8 column leading to considerably short separation time. L-alanine and Cu2+ were applied as chiral selector and central bivalent complexing ion, respectively. It was found that the kind of co...
متن کاملIon Exchange Column Performance Model for Separation of Zr(IV) and Hf(IV) in Elution Process
A mathematical model of sorption of Zirconium and Hafnium cations mixture and elution of these ions from a cation exchange resin bed is developed. Sulfuric acid is selected as the eluent for selective separation of Zr and Hf in a packed bed of Dowex cation exchange resin. The column model is a dispersed plug flow model,and assumed to consist of randomly packed synthetic and spherical resin ...
متن کاملDevelopment of a New Method Based on Chiral Ligand-Exchange Chromatography for the Enantioseparation of Propranolol
A new chromatographic procedure was proposed for the separation of propranolol (PRN) enantiomers based upon enantioselective chiral ligand-exchange chromatography. The separation was carried out on a short C8 column leading to considerably short separation time. L-alanine and Cu2+ were applied as chiral selector and central bivalent complexing ion, respectively. It was found that the kind of co...
متن کاملAn improved ion chromatographic method for fast and sensitive determination of N-methylpyrrolidine in cefepime hydrochloride.
An alternative ion chromatographic method to the existing USP method for the determination of N-methylpyrrolidine (NMP) in cefepime hydrochloride is developed. The cefepime in solution behaves as a strong cation and gets retained in the analytical column, leading to reduction in column capacity and irreproducible retention time. The retained drug has to be removed with a special rinsing solutio...
متن کامل