First alternative method validated by a retrospective weight-of-evidence approach to replace the Draize eye test for the identification of non-irritant substances for a defined applicability domain.
نویسندگان
چکیده
A replacement alternative to the rabbit eye irritation test has been sought for many years. First published in 1944 by FDA toxicologist J. H. Draize, the test, now known as the Draize Eye Test, has been used extensively to assess eye safety. It has also been a focal point for concern regarding its animal use. In 1992, Molecular Devices developed the Cytosensor Microphysiometer (CM) technology, an automated potentiometric online measurement of pH changes in cells, and evaluated it also for chemically induced irritation. The method was included in some of the six major validation studies for eye irritation from 1991-1997. The results for CM were inconclusive as were those from other tests evaluated as stand-alone methods to fully replace the animal test. In 2002, the European Centre for the Validation of Alternative Methods (ECVAM) started applying concepts from evidence-based medicine, and opened validation to retrospective meta-analysis. This activity was done in collaboration with US counterpart ICCVAM/NICEATM, and the European Cosmetics Association, Colipa. After a new, comprehensive evaluation of the prior available data, the ECVAM scientific advisory committee (ESAC) has recently accepted the CM as capable of identifying non-irritants for testing limited to water-soluble surfactants and water-soluble surfactant-containing mixtures. This 25-year development is remarkable and instructive in many respects. The authors see this as opening the door, at last, for an end to the use of animals as a standard requirement for eye irritation. Here, several of the people critically involved in this processes have summarized the important aspects of this history.
منابع مشابه
Analysis of Draize Eye Irritation Testing and its Prediction by Mining Publicly Available 2008–2014 REACH Data
Public data from ECHA online dossiers on 9,801 substances encompassing 326,749 experimental key studies and additional information on classification and labeling were made computable. Eye irritation hazard, for which the rabbit Draize eye test still represents the reference method, was analyzed. Dossiers contained 9,782 Draize eye studies on 3,420 unique substances, indicating frequent retestin...
متن کاملAnalysis of Draize Eye Irritation Testing and its Prediction by Mining Publicly Available 2008 - 2014 REACH Data 1
Public data from ECHA online dossiers on 9,801 substances encompassing 326,749 experimental key studies and additional information on classification and labeling were made computable. Eye irritation hazard, for which the rabbit Draize eye test still represents the reference method, was analyzed. Dossiers contained 9,782 Draize eye studies on 3,420 unique substances, indicating frequent retestin...
متن کاملThe Isolated Chicken Eye test to replace the Draize test in rabbits.
In 1944, Draize et al., published a paper entitled "Methods for the study of irritation and toxicity of substances applied topically to the skin and mucous membranes". The Organization for Economic Co-operation and Development published their first guideline on eye irritation in 1981, using rabbits. In the early eighties the development of alternative non-animal tests to replace the Draize eye ...
متن کاملAlternatives to In Vivo Draize Rabbit Eye and Skin Irritation Tests with a Focus on 3D Reconstructed Human Cornea-Like Epithelium and Epidermis Models
Human eyes and skin are frequently exposed to chemicals accidentally or on purpose due to their external location. Therefore, chemicals are required to undergo the evaluation of the ocular and dermal irritancy for their safe handling and use before release into the market. Draize rabbit eye and skin irritation test developed in 1944, has been a gold standard test which was enlisted as OECD TG 4...
متن کاملQSAR Study of 17β-HSD3 Inhibitors by Genetic Algorithm-Support Vector Machine as a Target Receptor for the Treatment of Prostate Cancer
The 17β-HSD3 enzyme plays a key role in treatment of prostate cancer and small inhibitorscan be used to efficiently target it. In the present study, the multiple linear regression (MLR),and support vector machine (SVM) methods were used to interpret the chemical structuralfunctionality against the inhibition activity of some 17β-HSD3inhibitors. Chemical structuralinformation were described thro...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- ALTEX
دوره 27 1 شماره
صفحات -
تاریخ انتشار 2010