Individualised headband simulation test for predicting outcome after percutaneous bone conductive implantation.

نویسندگان

  • S Monini
  • C Filippi
  • F Atturo
  • M Biagini
  • A I Lazzarino
  • M Barbara
چکیده

Trans-cutaneous bone conduction (BC) stimulators, when coupled to the HB (BC-HB), are generally used to predict the results that could be achieved after bone conductive implant (BCI) surgery, and their performance is generally considered inferior to that provided by the definitive percutaneous system. The aim of the present study was to compare the performances between BC-HB and BCI of the same typology, when the former's sound processor is fitted in accordance to the individual auditory situation. Twenty-two patients selected for surgical application of a BCI were evaluated and the same audiological protocol was used to select the candidate and assess the final outcome. The BC-HB was properly fitted based on individual hearing loss and personal auditory targets, and tested as primary step of the protocol to obtain the most reliable predictive value. The BAHA Divino and BP100 sound processors were applied in 12 patients with conductive/mixed hearing loss (CMHL) and in 10 subjects with single sided deafness (SSD). Audiometric evaluation included the pure tone average (PTA3) threshold between 250-1000 Hz; the PTA thresholds at 2000 and 4000 Hz; intelligibility scores as percentage of word recognition (WRS) in quiet and in noise; and subjective evaluation of perceived sound quality by a visual analogue scale (VAS). Statistical evaluation with a student's t test was used for assessment of efficacy of BC-HB and BCI compared with the unaided condition. Spearman's Rho coefficient was used to confirm the reliability of the BC-HB simulation test as a predictor of definitive outcome. The results showed that the mean PTA difference between BCI and BC-HB ranged from 2.54 to 8.27 decibels in the CMHL group and from 1.27 to 3.9 decibels in the SSD group. Compared with the BC-HB, BCI showed a better WRS both in CMHL (16% in quiet and 12% in noise) and in SSD (5% in quiet and a 1% in noise) groups. Spearman's Rho coefficient, calculated for PTA, WRS in quiet and in noise and VAS in the two aided conditions, showed a significant correlation between BC-HB and BCI, between PTA and VAS and between WRS in quiet and VAS. It is possible to conclude that the headband test, when the sound processor of the selected bone conductive implant is fitted and personalised for individual hearing loss and auditory targets of the candidate, may provide highly predictive data of the definitive outcome after BCI implant surgery.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Prediction of Speech Recognition in Noise With a Semi-Implantable Bone Conduction Hearing System by External Bone Conduction Stimulation With Headband

Semi-implantable transcutaneous bone conduction devices are treatment options for conductive and mixed hearing loss (CHL/MHL). For counseling of patients, realistic simulation of the functional result is desirable. This study compared speech recognition in noise with a semi-implantable transcutaneous bone conduction device to external stimulation with a bone conduction device fixed by a headban...

متن کامل

Analysis of factors predicting the success of the bone conduction device headband trial in patients with single-sided deafness.

OBJECTIVE To determine factors predicting whether patients with single-sided deafness (SSD) opt for a bone conduction device (BCD) for the contralateral routing of sound (CROS) after a regular trial with a BCD on a headband. DESIGN Retrospective case-control study. SETTING Nijmegen, the Netherlands. PATIENTS Thirty consecutive patients with SSD. INTERVENTIONS Patients received a trial w...

متن کامل

Comment on “Original Solution for Middle Ear Implant and Anesthetic/Surgical Management in a Child with Severe Craniofacial Dysmorphism”

With great interest we read the recently published article by Bianchin et al. describing a case report of a child with Van Maldergem Syndrome causing severe craniofacial dysmor-phism and bilateral congenital conductive hearing loss due to microtia and external auditory canal atresia [1]. Auditory restoration with a conventional skin-drive bone-conduction device, attached to a steel spring headb...

متن کامل

clinical and radiographic methods of marginal bone loss evaluation after immediate implantation in post-extraction sockets.

Introduction: To achieve the best esthetic and functional results of implantation and patient satisfaction, different protocols of implant therapy have been recommended. Immediate implantation can provide the outcome faster than other protocols making it the treatment of choice. The rate of peri-implant bone resorption should be measured clinically and radiographically as bone support is a key ...

متن کامل

Active Bone Conduction Prosthesis: Bonebridge

Bone conduction implants are indicated for patients with conductive and mixed hearing loss that do not benefit from conventional hearing aids or for those that cannot use them for anatomy abnormalities or medical conditions. These implants are also indicated for patients with single-sided deafness (SSD), which consists of one ear with profound hearing loss and the contralateral with normal hear...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Acta otorhinolaryngologica Italica : organo ufficiale della Societa italiana di otorinolaringologia e chirurgia cervico-facciale

دوره 35 4  شماره 

صفحات  -

تاریخ انتشار 2015