An automated dry-slide enzymatic method evaluated for measurement of creatinine in serum.

نویسندگان

  • J Toffaletti
  • N Blosser
  • T Hall
  • S Smith
  • D Tompkins
چکیده

We evaluated an automated dry-slide enzymatic method involving creatinine iminohydrolase for measurement of creatinine in serum with the Kodak Ektachem analyzer. The means (and SD) for three commercially available quality-control sera, analyzed during eight weeks, were 9.7 (1.0), 16.6 (0.9), and 61 (2.1) mg/L. The regression equation for 105 samples measured with the Technicon SMAC (x) and Ektachem Analyzers (y) was: y = (0.89 +/- 0.007)x + (1.7 +/- 0.3) mg/L and for 170 samples measured with the Beckman Astra (x) and Ektachem analyzers (y): y = (1.00 +/- 0.005)x - (1.9 +/- 0.16) mg/L. Sixty-one samples from renal-transplant patients showed nearly the same agreement. The enzymatic method had no interference from substances that interfere with many Jaffé methods for creatinine, including acetoacetate. The drugs cephalothin and cephoxitin did not interfere, but 5-fluorocytosine interfered significantly with creatinine in the Ektachem method. Values for several ketone-positive sera were 5 to 10 mg/L higher by the Astra relative to the Ektachem. Grossly hemolyzed or lipemic samples were analyzed without difficulty. We conclude that this enzymatic method for creatinine in serum has the speed and precision necessary for routine clinical laboratory use and, except for one drug, the method appears to be specific for creatinine.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مطالعه سیستاتین C سرم و کراتینین سرم به عنوان شاخص مطمئن در تشخیص نارسایی کلیوی بیماران فشار خونی

    Background & Aims : In the past serum creatinine concentration was used as one of the important markers for early detection of kidney disorders, however recent studies suggest serum cystatin C to be a better marker. Therefore in this study we compared the diagnostic value of cystatin C with serum creatinine to evaluate kidney function in patients with high blood pressure.   Materials & Meth...

متن کامل

A step forward in enzymatic measurement of creatinine.

We describe an improved enzymatic ultraviolet absorbance method for assaying creatinine in serum, plasma, and urine. Creatinine is hydrolyzed by creatinine iminohydrolase (EC 3.5.4.21) to ammonia and N-methylhydantoin. The ammonia produced combines with 2-oxoglutarate and NADPH in the presence of glutamate dehydrogenase to yield glutamate and NADP+. The consumption of NADPH, measured by a two-p...

متن کامل

Assessment of renal function by inulin clearance: comparison with creatinine clearance as determined by enzymatic methods.

We compared creatinine clearances determined by enzymatic (Kodak Ektachem 700 single-slide, Boehringer Mannheim creatinine PAP) and nonenzymatic (Jaffé, HPLC) methods with glomerular filtration rate measured by inulin clearance in patients with varying degrees of renal function. The Kodak enzymatic assay gave values for creatinine 2 to 3 mg/L higher than the other methods. This resulted in sign...

متن کامل

New Enzymatic Colorimetric Method for the Quantitative Determination of Phenylalanine in Dry-Blood Spots

Phenylketonuria (PKU) is an autosomal recessive disorder, which is characterized by severe mental retardation, microcephaly and seizures. The symptoms of this disease can be prevented if detected soon after birth. Therefore, blood Phenylalanine (Phe) measurement is essential for the early diagnosis, treatment and dietary monitoring of PKU patients. The goal of this research was to introduce a r...

متن کامل

Quantitative Bacterial Micro-Assay for Rapid Diagnosis of Galactosemia: Application in Galactosemia Neonatal Screening

In the present study a new economic and rapid bacterial micro-assay for simultaneous detection and quantitative measurement of serum galactose was developed. Analysis of the standard curve showed a linearity range for galactose from 2 mg/dL to 180 mg/dL with a regression equation of Y = 0.013X ? 0.083; R² = 0.962. The advantage of the method is its ability to measure serum galactose quantitativ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 29 4  شماره 

صفحات  -

تاریخ انتشار 1983