Prognostic value of preoperative right ventricular geometry and tricuspid valve tethering area in patients undergoing tricuspid annuloplasty.

نویسندگان

  • Kai-Hang Yiu
  • Arthur Wong
  • Lijun Pu
  • Man-Fung Chiang
  • Ko-Yung Sit
  • Daniel Chan
  • Hou-Yee Lee
  • Yui-Ming Lam
  • Yan Chen
  • Chung-Wah Siu
  • Chu-Pak Lau
  • Wing-Kok Au
  • Hung-Fat Tse
چکیده

BACKGROUND Patients who undergo tricuspid annuloplasty during left-side heart valve surgery have a poor postoperative clinical outcome. However, preoperative right ventricular (RV) echocardiography parameters that predict adverse events in these patients are poorly understood. METHODS AND RESULTS We studied 74 patients (age, 58±10 years; men, 27%) with significant tricuspid regurgitation who consequently underwent tricuspid annuloplasty during left-side heart valve surgery. A total of 26 adverse events (22 heart failures and 4 cardiovascular deaths) occurred during a median follow-up of 26 months. RV midcavity diameter (hazard ratio=2.44; 95% confidence interval=1.48-4.02; P<0.01), RV longitudinal dimension (hazard ratio=1.64; 95% confidence interval=1.10-2.45; P=0.02), and tricuspid valve tethering area (hazard ratio=3.25; 95% confidence interval=1.71-6.19; P<0.01) were independently associated with adverse events after adjustment for age and New York Heart Association class III/IV. Receiver-operator characteristic curve analysis demonstrated that RV midcavity diameter (area under the curve=0.74; P<0.01) and tricuspid valve tethering area (area under the curve=0.70; P=0.04) were most associated with adverse events at the 1-year follow-up. The presence of either a large RV midcavity diameter or tricuspid valve tethering area was predictive of adverse outcome at 1 year after tricuspid annuloplasty. CONCLUSIONS The present study demonstrates that RV geometry dimensions, namely RV midcavity diameter and tricuspid valve tethering area, are important preoperative measures associated with adverse events in patients undergoing tricuspid annuloplasty.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prognostic Value of Preoperative Right Ventricular Geometry and Tricuspid Valve Tethering Area in Patients Undergoing Tricuspid Annuloplasty Running title: Yiu et al.; Preoperative Tricuspid Annuloplasty

Division of Cardiology, Dept of Medicine, the University of Hong Kong, Queen Mary Hospital, Hong Kong, China; Research Centre of Heart, Brain, Hormone and Healthy Aging, Li Ka Shing Faculty of Medicine, the University of Hong Kong, Hong Kong, China; Dept of Medicine, Affiliated Hospital of North Sichuan Medical College, Sichuan, China; Dept of Surgery, the University of Hong Kong, Queen Mary Ho...

متن کامل

Tricuspid valve tethering predicts residual tricuspid regurgitation after tricuspid annuloplasty.

BACKGROUND Tricuspid valve (TV) annuloplasty is recommended for functional tricuspid regurgitation (TR), which is caused by TV annulus dilatation and tethering of the leaflets. However, the impact of TV deformations on the outcome of TV annuloplasty remains unknown. The goal of this study was to investigate the relationship between preoperative TV deformation and residual TR after TV annuloplas...

متن کامل

Determinants of recurrent or residual functional tricuspid regurgitation after tricuspid annuloplasty.

BACKGROUND The durability of tricuspid valve (TV) repair by annuloplasty is limited. Identification of mechanisms of recurrent or residual tricuspid regurgitation (TR) after annuloplasty is necessary to improve results of TV repair. The purpose of this study was to investigate echocardiographic determinants of mid-term outcome after TV annuloplasty. METHODS AND RESULTS This study consisted of...

متن کامل

Tricuspid leaflet augmentation to address severe tethering in functional tricuspid regurgitation.

This paper describes a technique for treating severe tricuspid regurgitation due to severe tethering of the tricuspid valve leaflets. The anterior tricuspid leaflet is augmented by use of an autologous pericardial patch, which increases its size, and hence its surface area of coaptation, allowing increased leaflet coaptation to occur with reduced tension within the right ventricle. A Carpentier...

متن کامل

Outcomes of ring versus suture annuloplasty for tricuspid valve repair in patients undergoing mitral valve surgery.

OBJECTIVE There is controversy regarding the comparative effectiveness of methods of tricuspid valve (TV) repair-prosthetic ring versus suture annuloplasty-in patients undergoing operation for primary mitral valve (MV) disease. In this study, we analyzed factors associated with patient survival and recurrent tricuspid regurgitation (TR) following TV repair and focused on results stratified by m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 129 1  شماره 

صفحات  -

تاریخ انتشار 2014