Reliability of preoperative planning of an image-guided system for oral implant placement based on 3-dimensional images: an in vivo study.

نویسندگان

  • Thomas Fortin
  • Jean Luc Bosson
  • Jean Loup Coudert
  • Michel Isidori
چکیده

PURPOSE The purpose of this study was to assess the reliability of the planning software of an image-guided implant placement system based on a mechanical device coupled with a template stabilized on soft tissue during surgery. MATERIALS AND METHODS Thirty consecutive partially or completely edentulous patients were treated with the image-guided system. For each patient, a study prosthesis was fabricated and duplicated in acrylic resin and served as a scanning template. Axial images were obtained from a computerized tomographic scan and transferred to planning software that provides real 3-dimensional information to plan implant position. Once the final position of the implant was defined, preoperative data such as the size of implants and anatomic complications were recorded using the planning software. The scanning template was then drilled in that exact position by a drilling machine. During surgery, the drilled template was used as a drill guide. After implant placement, intraoperative data were recorded and statistically compared with the preoperative data using the Kendall correlation coefficient for qualitative data and the Kappa concordance coefficient for quantitative data. RESULTS Agreement between the preoperative and intraoperative data was high for both implant size and anatomic complications. The Kendall correlation coefficient was 0.8 for the diameter and 0.82 for the length. The Kappa concordance coefficient was 0.87 for both dehiscence and bone graft, 0.88 for osteotomy, and 1.0 for fenestration. DISCUSSION In the few instances where planning was not perfect, implant placement was completed in a clinically acceptable manner. CONCLUSION The results suggest that the image-guided system presented is reliable for the preoperative assessment of implant size and anatomic complications. It may also be reliable for flapless surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Does cone-beam CT alter treatment plans? Comparison of preoperative implant planning using panoramic versus cone-beam CT images

PURPOSE The present study was performed to compare the planning of implant placement based on panoramic radiography (PAN) and cone-beam computed tomography (CBCT) images, and to study the impact of the image dataset on the treatment planning. MATERIALS AND METHODS One hundred five partially edentulous patients (77 males, 28 females, mean age: 46 years, range: 26-67 years) seeking oral implant...

متن کامل

Evaluation of the gray level in CBCT systems and its relationship with HU in CT Scanners

Introduction: Cone-beam CT (CBCT) is an imaging system which offers three-dimensional (3D), multiplanar images and has many advantages over computed tomography (CT) including shorter acquisition times for the resolution desired in dentistry, lower radiation dose to the patient, reasonable price and higher spatial resolution but CBCT scanners are unable to display actual Hounsf...

متن کامل

Accuracy of drilling guides for transfer from three-dimensional CT-based planning to placement of zygoma implants in human cadavers.

The accuracy of surgical drilling guides was assessed for placement of zygoma implants. Six zygoma fixtures of length 45 mm (Nobel Biocare, Göteborg, Sweden) were placed in three formalin-fixed human cadavers using surgical drilling guides. The fabrication of these custom-made drilling guides was based on three-dimensional computerized tomography (3D-CT) data for the maxillary-zygomatic complex...

متن کامل

Transfer precision of three-dimensional implant planning with CT assisted offline navigation.

AIM Computer-assisted surgery (CAS) is used in implant dentistry for preoperative planning and intraoperative transfer of the correct implant position. Implant placement is performed via sleeve-guided templates in the case of static navigation procedures by taking into consideration prosthetics and the amount of local bone. The aim of the present in vitro study was to analyze the transfer preci...

متن کامل

Standard edge detection algorithms versus conventional auto-contouring used for a three-dimensional rigid CT-CT matching

Background: To reduce uncertainties of patient positioning, the Computerized Tomography (CT) images acquired at the treatment planning time can be compared with those images obtained during radiation dose delivery. This can be followed during dose delivery procedure as Image Guided radiotherapy (IGRT) to verify the prescribed radiation dose delivery to the target as well as to monitor ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The International journal of oral & maxillofacial implants

دوره 18 6  شماره 

صفحات  -

تاریخ انتشار 2003