Component positions affect in vivo stability of Total Hip Arthroplasty
ثبت نشده
چکیده
INTRODUCTION: Dislocation continues to be a common complication of total hip arthroplasty (THA), affecting 2% to 11% of primary cases. Many factors affect the prevalence of dislocation after THA, including soft tissue laxity, surgical approach, component position, patient factors, and component designs [1,2]. Many in vitro studies have reported the range of motion (ROM) of the hip, impingement, and dislocation mechanisms, and several studies have reported the ROM and dislocation mechanisms in vivo [3,4]. Recently, we investigated the dislocation mechanisms in vivo using shape matching technique [3], and also measured intraoperative passive hip force using sensorinstrumented femoral head for analyzing the dislocation mechanisms [5,6]. Sultan et al. reported increased intraoperative ROM using elevated-rim acetabular liner and large diameter femoral head [4]. However, to the best of our knowledge, it has not been reported the relationship between the component positions and in vivo ROM and intraoperative stability. Our objective was to investigate the relationship between the component positions and in vivo ROM and stability. MATERIALS AND METHODS: 102 hips (100 patients) undergoing primary THA between May 2009 and July 2011 were enrolled in this study. The project was approved by IRB. All of the procedures were performed in a lateral decubitus position, using a posterolateral approach without trochanteric osteotomy. All components were determined intraoperatively in a standard fashion, then fixed into position. The acetabular component was inserted with a line-to-line fit or 0.5mm under reaming, and was intended to be placed at 45° of abduction and 20° of anteversion. Femoral neck length and offset were determined based on preoperative templating, then minor adjustments were made intraoperatively when necessary to optimize abductor tension to achieve optimal stability. Total capsulectomy was performed, and an effort was made to remove any osteophytes that were deemed to be potential causes of postoperative impingement. After all components were placed into position, the femoral head was observed independently by the assistant surgeon while the hips were ranged by the senior surgeon. The point of instability was determined by direct visual inspection and was predefined as the position at which the femoral head began riding out of the liner. With a 90° flexion of the hip joint, the range of internal rotation with 0° abduction/adduction was measured using a goniometer (IR angle), similar to Sultan et al. [4]. Hips also were tested for anterior dislocation in the position of maximum external rotation of 0° extension. During this time, senior surgeon operated 139 THAs at one hospital. To be included in the analysis, the following was required: primary THA, single surgeon, ROM data available, and Computed tomography (CT) data available. During this time, CT scanning was routinely performed 1 to 2 weeks after the surgery. 37 hips were excluded, so 102 hips were included and analyzed in this study. The average age at the time of operation was 63 years (39 to 87). Their average weight and height were 57.8 kg (37.8 to 88.6) and 154 cm (133 to 180). Twenty three patients were men and 77 were women. There were 52 right hips and 50 left hips. The diagnosis was osteoarthritis in 83 (81.2%), osteonecrosis of the femoral head in 9 (8.8%), rheumatoid arthritis in 5, and femoral neck fracture in 4, and rapidly destructive coxopathy in 1. Eighty four (82%) femoral components were cemented (4-U; Nakashima Medical Co., Japan) [7,8] and 18 uncemented (S-ROM; Depuy, IN). All acetabular components were uncemented. There were 70 4-U cup (Nakashima Medical Co.), 25 Trilogy cup (Zimmer, IN), and 7 ZTT-2 cup (Depuy). The diameter of the prosthetic femoral head was 22 mm in 1 hip, 26 mm in 73 hips, 28mm in 12 hips, and 32mm in 15 hips. The average outer diameter of the acetabular component was 55mm (42-60). The standard flat liner was used in 49 hips and the elevated liner was used in 52. The following variables were measured and investigated: (a)cup abduction; (b)cup anteversion; (c)stem anteversion; (d)femoral head diameter; (e)liner type (flat vs elevated). Cup anteversion and stem anteversion were measured from CT data, according to the method of Mian et al. [9] and the method of Pierchon et al. [10]. The abduction angle of the cup was measured according to the method of Lewinnek et al. [11], respectively. Statistical analysis. The Pearson correlation coefficient was used to assess correlation between variables and ROM (IR angle). Then, multivariate analysis (stepwise linear regression) was used to determine which variables influenced ROM (IR angle). Variables that were nonsignificant predictors of the ROM outcome were eliminated in a stepwise fashion until only those that were significant remained. Thus, variables included in the final linear regression model were all significant copredictors of the ROM. Statistical analyses were performed with SPSS Version 19 (SPSS Inc, IL). RESULTS: Mean IR angle was 57° (15-91). None of the hips could be dislocated anteriorly during ROM testing. The mean cup abduction was 42.1° (24 to 60). Mean cup anteversion was 16.6° (-20 to 57), retroversion of the cup was found in 10. The mean stem anteversion was 39.1° (1 to 67). Cup abduction, cup anteversion, and stem anteversion were significantly and positively related to IR angle (p=0.011; r=0.228) (p=0.018; r=0.207) (p=0.000; r=0.532). We could demonstrate no significant correlation between head size and IR angle, liner type and IR angle. Multiple regression was used to determine the relative importance of each of the variables. Cup abduction, cup anteversion, and stem anteversion predicted the IR angle. Increasing cup abduction, cup anteversion, and stem anteversion correlated with increased IR angle. Interpretation of the standardized coefficients in the regression model, which are a measure of each variable’s effect on the dependent variable, revealed stem anteversion had the strongest effect on the IR angle, followed by cup abduction, and cup anteversion (Table 1).
منابع مشابه
Total Hip Arthroplasty with Modular Stem for Dysplastic Hips in South Asian Population
Introduction: Optimum component positioning and orientation is required to optimize the functional result during total hip arthroplasty for dysplastic hips. Patients and methods: Sixty-two patients (66 hips) including 33 males and 29 females underwent total hip arthroplasty using modular stem prosthesis at an average age of 40.6 years (range 17 to 49 years). Nineteen hips were clas...
متن کاملA Single Femoral Component for All Total Hip Replacements Performed by a Trust? Does This Affect Early Clinical and Radiological Outcomes?
Background: Hospitals may be under pressure to implement cost saving strategies regarding prosthesis choice. Thismay involve the use of components which are not the first preference of individual surgeons, or those they have littleexperience with. We aim to examine the effect of standardizing the type of femoral stem used in a single trust, anddetermine whether this is safe practice, particular...
متن کاملPartial 2-Stage Revision in Chronic Hip Arthroplasty Infections: A Review
Background: Periprosthetic hip infections (PHIs) are troublesome complications of hip arthroplasties. The gold standard procedure for treating chronic PHI is a 2-stage approach. Recently, however, more conservative approaches have been developed to spare the osseointegrated components and avoid sequestra, bone loss, devascularization, and difficult reconstructions. The partial ...
متن کاملHip Arthroplasty and its Revision in a Child: Case Report and Literature Review
Juvenile idiopathic arthritis is the leading cause of hip replacement in young children. However, arthroplasty in this population is challenging with several concerns about quality of the growing bone, young age for revision surgery, and difficulties in potential several revisions. In this study we introduce a case of a 12-year old who is one of the youngest patients to undergo revision hip art...
متن کاملBone density study of the proximal femur after hip arthroplasty with porous-coated implants
Progressive loss of bone mineral density around the femora! component of total hip replacement continues to pose a threat to long term prosthetic survival. A linear study was undertaken to measure bone mineral density on a monthly basis following total hip arthroplasty in 11 male patients. The opposite femur was used as the control measurement. Bone mineral density was unchanged at two mo...
متن کاملJoint motion and surface contact area related to component position in total hip arthroplasty.
A three-dimensional computer model of a total hip replacement was used to examine the relationship between the position of the components, the range of motion and the prosthetic joint contact area. Horizontal acetabular positions with small amounts of acetabular and femoral anteversion provide the largest contact areas, but result in limited joint movement. These data will allow surgeons to sel...