Comparison of Accuracy of determining the Distance between Alveolar Crest and Cementoenamel Junction in Digital Radiography with Scanora and DentalEye Software Programs.
نویسندگان
چکیده
AIM To compare the accuracy of determining the distance between alveolar crest and cementoenamel junction (CEJ) in digital radiography with two image processing software programs. MATERIALS AND METHODS In this in vitro study, 63 sites in a dried human mandible underwent digital periapical radiography. The distance from the alveolar crest to the CEJ was calculated using DentalEye and Scanora software programs and compared with the standard mode (measured on the skull). Statistical analysis was performed with analysis of variance (ANOVA) and paired t-test using Statistical Package for the Social Sciences (SPSS) 23 at α = 0.05. RESULTS There were significant differences in the distances between CEJ and the alveolar crest at the mesial surfaces as measured by the three techniques in standard mode, using DentalEye and Scanora (p-value ≤ 0.03) softwares; however, there were no significant differences between the results on distal surfaces (p-value = 0.248). CONCLUSION Under the limitations of the present study, the measurements made to determine the distance from the CEJ to the alveolar crest with DentalEye and Scanora, relative to each other, and relative to the standard mode, were accurate only on distal surfaces of teeth. CLINICAL SIGNIFICANCE Digital dental software programs are useful assets that can enhance the diagnosing ability and reduce the need of taking extra images.
منابع مشابه
ارزیابی همبستگی فاصله کرست استخوان آلوئول تا CEJ در رادیوگرافیهای پریایپکال، پانورامیک و بایتوینگ با میزان واقعی آن
Statement of Problem: In spite of the limitations of Radiography, diagnosing of periodontal diseases without having accurate radiographs is inadequate because it provides a visible image of the supporting bone to the clinician and works as a fixed measure of the supporting bone during the study.Purpose: The aim of this study is to compare the precision of preiapical, bitewings and panoramic rad...
متن کاملارزیابی دقت رادیوگرافی بایتوینگ دیجیتال (CMOS) در سنجش تحلیل استخوان آلوئولار بیندندانی در دندانهای خلفی
Background and ObjectiveRadiographic examination has an important role in diagnosis and treatment of periodontal patients, so this study was performed to determine the accuracy of digital bite wing (CMOS) radiography in alveolar bone resorption. Materials and Methods: This cross-sectional study was performed on 61 teeth of 16 periodontal patients referred to the periodontoloy department of R...
متن کاملComparison of Diagnostic Accuracy of Cone Beam Computed Tomography and Digital Radiography for Detection of Vertical Root Fractures with and without Gutta Percha
Objective: Diagnosis of vertical root fractures (VRFs) is critical in endodontics which most of the times occurs in endodontically treated teeth with root canal fillings such as gutta percha. Despite Cone Beam Computed Tomography (CBCT) has significantly enhanced image quality compared to digital radiography (DR) which aid the diagnosis, artifacts has remained as a problem in VRF detection . ...
متن کاملبررسی و مقایسه دقت رادیوگرافی های پانورامیک، پری اپیکال و بایت وینگ در تعیین میزان تحلیل استخوان آلوئول در پریودنتیت
Introduction: The height of the alveolar bone, is normally maintained by equilibrium between bone formation and bone resorption, but in periodontal disease more destruction or lack of bone formation will reduce the alveolar bone height. However the radiography is important in diagnosis, treatment plan and detection of quality and quantity of the alveolar bone although the type of radiography is...
متن کاملبررسی مقایسه ای دقت فیلم های داخل دهانی با سرعت E، سیستم دیجیتال داخل دهانی PSP و سیستم های دیجیتال پانورامیک PSP و CCD در تعیین میزان تحلیل استخوان آلوئول در بیماران مبتلا به پریودنتیت مزمن
Introduction & Objective: Diagnosis of periodontal osseous lesions is very important in deter-mining prognosis, treatment plan and maintenance in the long term. This diagnosis can be achieved by using radiography. The aim of this study is to compare accuracy of E speed films, bitewing PSP, panoramic PSP and CCD for identifying the extent of destruction of alveolar bone in chronic periodontiti...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The journal of contemporary dental practice
دوره 17 10 شماره
صفحات -
تاریخ انتشار 2016