Light transmission aggregometry using pre-coated microtiter plates and a Victor X5 plate reader

نویسندگان

  • Pernille Just Vinholt
  • Mads Nybo
  • Camilla Brødsgaard Nielsen
  • Anne-Mette Hvas
چکیده

BACKGROUND Light transmission aggregometry (LTA) can be performed with microtiter plates (96-well LTA). When conducting LTA, an agonist is added to platelet-rich plasma and the sample is shaken for minutes after which absorbance readings are done. Platelet aggregation is detected as decrease in absorbance. However, the classical method is cumbersome and therefore microtiter plates can be used for concomitant testing of multiple samples. Furthermore, it would be convenient to prepare the plate in advance of platelet aggregation testing. Aim: The aim of the present study was to establish a simplified 96-well LTA protocol, where plates were pre-coated with agonists and stored at -80 C until use. RESULTS We developed and validated a protocol for 96-well LTA using a Victor X5 plate reader and pre-coated microtiter plates. The minimum requirement of platelet-rich plasma was 45 μL per sample and the sample platelet count should not be below 100 x109/L. Optimal absorbance reading was 595 nm wavelengths. Platelet aggregation results were higher at 37°C than at room temperature. Platelet adherence to wells after stimulation was observed; it was not avoided by pre-coating of the wells with gelatin. A range of up to 7 concentrations for each agonist (collagen, arachidonic acid, adenosine diphosphate, thrombin receptor-activating peptide and protease-activated receptor-4) was tested concomitantly. A transient rise in platelet aggregation was observed after 2 minutes of shaking in some samples with low agonist concentration, and platelet aggregation was optimal after 10 minutes of shaking for samples with high agonist concentration. Plates could be stored at -80°C for 15 days without significant change in the platelet aggregation results. CONCLUSION The 96-well LTA is suitable for platelet aggregation testing and a range of agonist concentrations can be concomitantly tested.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monitoring the effects of platelet glycoprotein IIb/IIIa antagonists with a microtiter plate method for detection of platelet aggregation.

Measurement of platelet aggregation in platelet-rich plasma (PRP) is a fundamental tool in platelet studies, despite the fact that the technique required for this is time-consuming, may need large volumes of blood, and require particular skill and special equipment. The use of a microplate reader seems useful to perform platelet aggregation more rapidly and with less material. So, the aim of th...

متن کامل

Inhibition of bacterial adherence to saliva-coated through plant lectins.

In the present study, we evaluated the ability of lectin from Talisia esculenta (TEL) and a protein from Labramia bojeri seeds (Labramin) to inhibit adherence of microorganisms and exert antimicrobial effects. The minimum inhibitory and bactericidal concentrations of these proteins were determined using 5 species of bacteria: Streptococcus mutans UA159, Streptococcus sobrinus 6715, Streptococcu...

متن کامل

Exact 3-D Solution for Free Bending Vibration of Thick FG Plates and Homogeneous Plate Coated by a Single FG Layer on Elastic Foundations

This paper presents new exact 3-D (three-dimensional) elasticity closed-form solutions for out-of-plane free vibration of thick rectangular single layered FG (functionally graded) plates and thick rectangular homogeneous plate coated by a functionally graded layer with simply supported boundary conditions. It is assumed that the plate is on a Winkler-Pasternak elastic foundation and elasticity ...

متن کامل

High-throughput and automated diagnosis of antimicrobial resistance using a cost-effective cellphone-based micro-plate reader

Routine antimicrobial susceptibility testing (AST) can prevent deaths due to bacteria and reduce the spread of multi-drug-resistance, but cannot be regularly performed in resource-limited-settings due to technological challenges, high-costs, and lack of trained professionals. We demonstrate an automated and cost-effective cellphone-based 96-well microtiter-plate (MTP) reader, capable of perform...

متن کامل

Direct hapten coated immunoassay format for the detection of atrazine and 2,4-dichlorophenoxyacetic acid herbicides.

A novel immunoassay format employing direct coating of small molecular hapten on microtiter plates is reported for the detection of atrazine and 2,4-dichlorophenoxyacetic (2,4-D). In this assay, the polystyrene surface of microtiter plates was first treated with an acid to generate -NO2 groups on the surface. Acid treated plates were further treated with 3-aminoprpyltriethoxysilane (APTES) to f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017