Dynamics of screw and plate interaction.
نویسنده
چکیده
Several papers in this issue of the Journal address topics in the theme of plate and screw fixation (1–4). A critical element of this form of internal fixation is that the maintenance of stability provided by the plate relies heavily on the integrity of the screw fixation. Bone screws can perform their work in several ways. In conventional plate fixation, the head of a tightened screw compresses the under-surface of the plate onto the underlying bone, creating friction between these three elements. The stability of the plate fixation relies on the maintenance of friction between the plate and bone. By contrast, locking plates do not rely on this plate-bone contact because the screw heads are locked into the plate hole. Indeed there may be a space of several millimetres under a locking plate, and the size of this space does not change unless implant failure occurs. These are two fundamentally different mechanisms of action for bone screws used with bone plates. During a surgical osteosynthesis, at the time when a bone plate is being applied to the bone, a potentially dynamic relationship exists between the screws, the plate and the bone. Each of the steps leading up to final insertion and tightening of the screws can have either planned or unintended consequences on the final resting position of the bone plate. Moreover, a change in plate position can affect the relationship between the bone fragments that are being stabilized, either in a favourable or undesirable manner. The best known example of this dynamic relationship is with the use of a compression bone plate to produce interfragmentary compression. Another example observed by Woodbridge and colleagues is the unplanned translation of tibial plateau levelling osteotomies with application of locking plates (4). The principle of the self-compressive bone plate was refined by the AO Foundation in Switzerland, resulting in the development of the dynamic compression plate, with each plate hole precisely machined with an internal glide path for the load or compression screw (5). Perren and colleagues showed in the transverse diaphyseal osteotomy ovine model that the application of a compression plate produced over 100 kg of interfragmentary compression, and that this did not result in bone necrosis but rather primary bone healing (5). There are many factors that can alter the magnitude of this interfragmentary compression, such as for example the angle of the screw axis with respect to the longitudinal axis of the bone plate. One of the design features of the dynamic compression plate hole is that it allows up to 25 degrees of angulation of the screw in a longitudinal plane, on either side of the perpendicular position. However, if the load screw in a dynamic compression plate is angled by 10 degrees or more in the longitudinal plane, such that the tip of the screw is directed away from the fracture gap, then the amount of interfragmentary compression is more than double that achieved by a perpendicular load screw (6). By contrast, if the load screw is directed by 10 degrees or more towards the fracture gap, then the amount of interfragmentary compression achieved drops to zero, with full tightening of the load screw (6). Furthermore the study reported by Jermyn and Roe found that prior application of a neutral screw in another more distal plate hole significantly diminished the magnitude of compression achieved by subsequent application of the load screw, even if the initial neutral screw had not been completely tightened initially (1). Therefore there are many potential technical pitfalls to consider during the execution of load screw insertion with bone plate osteosynthesis. The introduction of locking plates has been an important advance for fracture stabilization, especially in comminuted diaphyseal fractures. However the use of plates that allow for the generation of interfragmentary compression of reducible transverse fractures and osteotomies is still much preferred over locking plates that do not have this feature because of the reduced Kenneth A. Johnson
منابع مشابه
First Metatarsophalangeal Joint Arthrodesis: A Retrospective Comparison of Crossed-screws, Locking and Non-Locking Plate Fixation with Lag Screw
Background:Locking plate fixation is increasingly used for first metatarsophalangeal joint (MTP-I) arthrodesis. Still there is few comparable clinical data regarding this procedure. Methods:We retrospectively evaluated 60 patients who received an arthrodesis of the MTP-I between January 2008 and June 2010. With 20 patients each we performed a locking plate fixation with lag screw, arthrodesis w...
متن کاملTreatment of Displaced Sacroiliac Fracture Using the Lateral Window for Short Plate Buttress Reduction and Percutaneous Sacroiliac Screw Fixation.
Fractures through the sacroiliac joint are very challenging to treat, technically difficult to reduce through closed methods on account of the multiaxial displacement of fractures fragments, frequently occur in very unwell patients, and have poor outcomes if malreduction is present. We describe a technique utilising the lateral window and a short buttress plate to reduce and stabilize th...
متن کاملA Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate
Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking...
متن کاملپایداری فوری قدام مهره های گردن با متیل متاکریلات به جای پیچ و صفحه کاسپار
Background and purpose: The common method of stabilization in noncancerous lesions of anterior cervical vertebrae is the use of interbody bone graft and instulation of caspar plate and screws which is followed by several complications, breaking or loosing of screw, damage to esophagus and improper fusion of bone graft, as a result, damage to spinal cord during fixing the screw and also expous...
متن کاملFirst Metatarsophalangeal Joint Arthrodesis: A Retrospective Comparison of Crossed-screws, Locking and Non-Locking Plate Fixation with Lag Screw
Background:Locking plate fixation is increasingly used for first metatarsophalangeal joint (MTP-I) arthrodesis. Still there is few comparable clinical data regarding this procedure. Methods:We retrospectively evaluated 60 patients who received an arthrodesis of the MTP-I between January 2008 and June 2010. With 20 patients each we performed a locking plate fixation with lag screw, arthrodesis w...
متن کاملDevelopment of Mathematical Model for Controlling the Drilling Parameters with a Screw Downhole Motor
Article presents results of study on possibility of increasing the efficiency of drilling directional straight sections of wells using screw downhole motors (SDM) with a combined method of drilling with rotation of drilling string (DS). Goal is to ensure steady-state operation of SDM with simultaneous rotation of DS by reducing the amplitude of oscillations with adjusting the parameters of dril...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Veterinary and comparative orthopaedics and traumatology : V.C.O.T
دوره 24 6 شماره
صفحات -
تاریخ انتشار 2011