Controlled comparison of BACTEC 13A, MYCO/F LYTIC, BacT/ALERT MB, and ISOLATOR 10 systems for detection of mycobacteremia.
نویسندگان
چکیده
To compare the performance of the BACTEC 13A (Becton Dickinson, Sparks, Md.), BACTEC MYCO/F LYTIC (Becton Dickinson), BacT/ALERT MB (bioMérieux, Durham, N.C.), and ISOLATOR 10 lysis-centrifugation (Wampole Laboratories, Cranbury, N.J.) systems for detection of mycobacteremia in adults, we inoculated 5-ml aliquots of blood from patients with suspected mycobacteremia into the bottle or tube required for each system. Of 600 sets tested, 85 (14%) yielded Mycobacterium avium complex (MAC) and 9 (2%) yielded other species of mycobacteria. Of 26 complete (three bottles and one tube) adequately filled (5 +/- 1 ml) sets from which MAC was recovered, BACTEC 13A was positive for 19 (73%), BACTEC MYCO/F LYTIC was positive for 21 (81%), BacT/ALERT MB was positive for 22 (85%), and ISOLATOR 10 was positive for 21 (81%). Of the six possible two-way comparisons, the mean times to detection for the recovery of MAC from each bottle in positive adequately paired sets were 15.3 days for BACTEC 13A versus 12.8 days for MYCO/F LYTIC for 33 of 340 pairs, 14.1 days for BACTEC 13A versus 11.6 days for BacT/ALERT MB for 38 of 380 pairs, 12.6 days for BACTEC 13A versus 20.0 days for ISOLATOR 10 for 26 of 261 pairs, 12.8 days for BACTEC MYCO/F LYTIC versus 11.0 days for BacT/ALERT MB for 33 of 340 pairs, 13.2 days for BACTEC MYCO/F LYTIC versus 20.4 days for ISOLATOR 10 for 24 of 230 pairs, and 9.9 days for BacT/ALERT MB versus 19.0 days for ISOLATOR 10 for 24 of 257 pairs. There were no significant differences in yields between the systems. However, the mean time to detection differed significantly among the systems. The time to detection was shortest for BacT/ALERT MB, followed by BACTEC MYCO/F LYTIC and BACTEC 13A and then ISOLATOR 10. Although the numbers were too small for statistical comparison, the time to detection was substantially shorter for MAC than for Mycobacterium tuberculosis complex in the liquid systems. The continuously monitored systems (BACTEC MYCO/F LYTIC and BacT/ALERT MB) were as sensitive and, on balance, faster for the detection of MAC bacteremia than were the heretofore standard manual ISOLATOR 10 and radiometric BACTEC 13A systems.
منابع مشابه
Controlled comparison of BacT/Alert MB system, manual Myco/F lytic procedure, and isolator 10 system for diagnosis of Mycobacterium tuberculosis Bacteremia.
We compared the performance of the BacT/Alert MB system, that of the manual Bactec Myco/F Lytic procedure, and that of the Isolator 10 lysis-centrifugation system in the detection of Mycobacterium tuberculosis bacteremia. Mean times to detection were 16.4 days for BacT/Alert MB versus 20.0 days for Myco/F Lytic, 16.5 days for BacT/Alert MB versus 23.8 days for Isolator 10, and 21.1 days for Bac...
متن کاملComparison of BACTEC 13A medium and Du Pont isolator for detection of mycobacteremia.
BACTEC 13A medium (Johnston Laboratories, Towson, Md.) was compared with Isolator (Du Pont Co., Wilmington, Del.) concentrate for sensitivity, speed, and technical ease of isolation of mycobacteria from paired patient blood samples. Of 72 positive cultures, 63 were positive by both systems. Five positive cultures were detected by BACTEC 13A medium alone, and four were detected by Isolator alone...
متن کاملComparison of BACTEC MYCO/F LYTIC and WAMPOLE ISOLATOR 10 (lysis-centrifugation) systems for detection of bacteremia, mycobacteremia, and fungemia in a developing country.
In less-developed countries, studies of bloodstream infections (BSI) have been hindered because of the difficulty and costs of culturing blood for bacteria, mycobacteria, and fungi. During two study periods (study period I [1997] and study period II [1998]), we cultured blood from patients in Malawi by using the BACTEC MYCO/F LYTIC (MFL), ISOLATOR 10 (Isolator), Septi-Chek AFB (SC-AFB), and Sep...
متن کاملEvaluation of BACTEC MYCO/F lytic medium for recovery of mycobacteria and fungi from blood.
The reliability of MYCO/F Lytic medium in the BACTEC 9240 blood culture system was evaluated by comparing its performance to that of the Isolator system for the recovery of fungi and to that of the ESP II system for the recovery of mycobacteria. Of 717 specimens of blood cultured for fungi, 24 were positive; 12 samples were positive with both systems, 7 samples were positive with the Isolator s...
متن کاملEvaluation of BACTEC MYCO/F Lytic medium for recovery of mycobacteria, fungi, and bacteria from blood.
MYCO/F Lytic medium (MFL), a liquid medium developed for use with the BACTEC 9240 blood culture system, was compared to the Isolator system (IS) for the recovery of fungi and to the BACTEC 13A medium for the recovery of mycobacteria. Recovery of bacteria was compared to routine BACTEC Plus Aerobic/F (AF) blood cultures. Microbial growth was detected in 203 (17%) of 1,166 blood cultures. Fifty-s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 41 5 شماره
صفحات -
تاریخ انتشار 2003