An impedance threshold device in out-of-hospital cardiac arrest.

نویسندگان

  • Massimiliano Greco
  • Giovanni Landoni
  • Luca Cabrini
چکیده

BACKGROUND The impedance threshold device (ITD) is designed to enhance venous return and cardiac output during cardiopulmonary resuscitation (CPR) by increasing the degree of negative intrathoracic pressure. Previous studies have suggested that the use of an ITD during CPR may improve survival rates after cardiac arrest. METHODS We compared the use of an active ITD with that of a sham ITD in patients with out-of-hospital cardiac arrest who underwent standard CPR at 10 sites in the United States and Canada. Patients, investigators, study coordinators, and all care providers were unaware of the treatment assignments. The primary outcome was survival to hospital discharge with satisfactory function (i.e., a score of ≤3 on the modified Rankin scale, which ranges from 0 to 6, with higher scores indicating greater disability). RESULTS Of 8718 patients included in the analysis, 4345 were randomly assigned to treatment with a sham ITD and 4373 to treatment with an active device. A total of 260 patients (6.0%) in the sham-ITD group and 254 patients (5.8%) in the active-ITD group met the primary outcome (risk difference adjusted for sequential monitoring, -0.1 percentage points; 95% confidence interval, -1.1 to 0.8; P=0.71). There were also no significant differences in the secondary outcomes, including rates of return of spontaneous circulation on arrival at the emergency department, survival to hospital admission, and survival to hospital discharge. CONCLUSIONS Use of the ITD did not significantly improve survival with satisfactory function among patients with out-of-hospital cardiac arrest receiving standard CPR. (Funded by the National Heart, Lung, and Blood Institute and others; ROC PRIMED ClinicalTrials.gov number, NCT00394706.).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Active compression-decompression resuscitation and impedance threshold device for out-of-hospital cardiac arrest: a systematic review and metaanalysis of randomized controlled trials.

OBJECTIVE Active compression-decompression resuscitation and impedance threshold device are proposed to improve survival of patients of cardiac arrest by lowering intrathoracic pressure and increasing cardiac output. The results of clinical studies of active compression-decompression resuscitation or impedance threshold device were controversial. This metaanalysis pooled results of randomized c...

متن کامل

Evaluation of an impedance threshold device in patients receiving active compression-decompression cardiopulmonary resuscitation for out of hospital cardiac arrest.

AIMS The purpose of this multicentre clinical randomized controlled blinded prospective trial was to determine whether an inspiratory impedance threshold device (ITD), when used in combination with active compression-decompression (ACD) cardiopulmonary resuscitation (CPR), would improve survival rates in patients with out-of-hospital cardiac arrest. METHODS AND RESULTS Patients were randomize...

متن کامل

Clinical evaluation of an inspiratory impedance threshold device during standard cardiopulmonary resuscitation in patients with out-of-hospital cardiac arrest.

OBJECTIVE To determine whether an impedance threshold device, designed to enhance circulation, would increase acute resuscitation rates for patients in cardiac arrest receiving conventional manual cardiopulmonary resuscitation. DESIGN Prospective, randomized, double-blind, intention-to-treat. SETTING Out-of-hospital trial conducted in the Milwaukee, WI, emergency medical services system. ...

متن کامل

Clinical Investigations Clinical evaluation of an inspiratory impedance threshold device during standard cardiopulmonary resuscitation in patients with out-of-hospital cardiac arrest*

An inspiratory impedance threshold device (ITD) has recently been demonstrated to enhance vital organ perfusion and neurologically intact survival rates in animals in cardiac arrest during standard cardiopulmonary resuscitation (CPR) (1– 4). The ITD is a small, 35-mL device that can attach to a variety of airway adjuncts, including a facemask and endotracheal tube (Fig. 1). By selectively imped...

متن کامل

Impact of impedance threshold devices on cardiopulmonary resuscitation: a systematic review and meta-analysis of randomized controlled studies.

OBJECTIVES Vital organ hypoperfusion significantly contributes to the dismal survival rates observed with manual cardiopulmonary resuscitation after cardiac arrest. The impedance threshold device is a valve which reduces air entry into lungs during chest recoil between chest compressions, producing a potentially beneficial decrease in intrathoracic pressure and thus increasing venous return to ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The New England journal of medicine

دوره 366 2  شماره 

صفحات  -

تاریخ انتشار 2011