EMC’04/Sendai Electromagnetic field near power line for a power line communication system
نویسندگان
چکیده
LCL and LCTL frequency characteristics for the balanced pair cable of power line communication system were measured for the several grounding conditions such as no, input side and output side groundings. In consequence, it is clear that the input side grounding for LCL became the worst, but the output side grounding for LCTL became the worst, and the tendency of the LCTL frequency characteristics is different from that of LCL. The Leaked E-field characteristics from the balanced pair cable were measured and calculated for the several grounding conditions, and it is revealed that the measurement and calculation results for the maximum additional amount of the leaked E-field compared with no grounding is also about 20dB by the input side grounding. In addition, it turns out that the leaked E-field becomes also large as LCTL gets worse, and the relation between LCTL and the leaked E-field depends on the grounding conditions such as no, input side and output side groundings. Key words; Power line communication, LCL, leaked electromagnetic field, grounding and method of moment
منابع مشابه
EMC’04/Sendai Characterization of AT railway traction power supply, measurement system and results
Tests at the new ‘Havenspoorlijn’ (Harbor Railway Line) in The Netherlands asked for the measurement of all currents at eight positions of the railway. The differentiating/integrating measurement scheme with Rogowski coils and special integrators fulfilled the requirements with respect to accuracy, bandwidth, electromagnetic compatibility, life-time and environmental constraints. The sensors al...
متن کاملEMC’04/Sendai Three-wire Analysis Model to Predict SI and EMC Effects
Accurate driver and package models are necessary to analyze the signal integrity (SI) and electromagnetic compatibility (EMC) issues on digital circuits. 2-wire models that assume an ideal power distribution system (PDS) are commonly used in modeling the SI of signal lines. This assumption makes real SI and EMC analysis worthless or at least only useful under certain restrictions. In order to a...
متن کاملهینهسازی مسیر هادیهای انتقال در محفظه فلزی تجهیزات الکتریکی مبتنی بر سازگاری الکترومغناطیسی با استفاده از روش تصمیمگیری چند معیاره مطالعه موردی: سیستم تزریق جریان 25 کیلو آمپر
The higher frequency transient signals generated as a result of a power system fault or disturbance provide the basis for an alternative approach to power system containing connectors and cables result in unsuitable operation of the system. However one major challenge is the need to ensure that the transients to be neutralized by electromagnetic compatibility (EMC) issues and cabling routes. T...
متن کاملInvestigation of Electromagnetic Interference from a Pulsed Solid State Laser Power Supply
This paper investigates the near field, far field and conducted electromagnetic emissions in a pulsed power supply circuit for a flash lamp pumped solid-state laser amplifier. The power supply consists of a charging circuit, which energizes 300 μF of energy storage capacitor bank to 3 kV. The stored energy is discharged through a flash lamp in the form of pulsed current. It is a single shot eve...
متن کاملA Suitable Coding Scheme for Broadband Power-line Communication
This paper introduces three coding strategies for using the Luby Transform (LT) code in a relay aided power-line communication scheme. In the first method, the relay decodes the received packets and re-encodes them for transmission towards the destination. In the second method, the relay only forwardes a random linear combination of its received packets towards the destination, while in the thi...
متن کامل