Comparison of conventional PCR with real-time PCR and branched DNA-based assays for hepatitis C virus RNA quantification and clinical significance for genotypes 1 to 5.
نویسندگان
چکیده
The key parameter for diagnosis and management of hepatitis C virus (HCV) infection is HCV RNA. Standardization of HCV RNA assays to IU is mainly based on genotype 1 panels. Little is known about the variability of commercially available HCV RNA assays for quantification of different genotypes. Two real-time reverse transcription (RT)-PCR assays (COBAS TaqMan HCV Test for use with the High-Pure System [HPS/CTM] and COBAS Ampliprep/COBAS TaqMan HCV Test [CAP/CTM]), one standard RT-PCR assay (COBAS Amplicor HCV Monitor 2.0 [CAM]), and one signal amplification assay (Versant Quantitative 3.0 [branched DNA [bDNA]]) were compared for quantification of genotypes 1 to 5 (n = 108). Using CAM as a reference assay for genotype 1-infected patients, the mean interassay differences compared with CAP/CTM, HPS/CTM, and bDNA were 0.16, -0.13, and -0.48 log(10) IU/ml HCV RNA, respectively. Comparison of CAM with CAP/CTM, HPS/CTM, and bDNA for the remaining genotypes showed the following results, respectively: 2a/c, -0.24, -0.78, and -0.49; 2b, -0.21, -0.18, and -0.64; 3a, 0.13, -1.04, and -0.55; 4, -0.52, -1.51, and -0.05; and 5, -0.28, -1.00, and -0.24 log IU/ml HCV RNA. A correct decision for treatment discontinuation in genotype 1 patients at week 12 was possible only when the same assay was used at baseline and week 12. Comparison of CAM with the CAP/CTM assay showed equal quantifications of genotype 1, 2, 3, and 5 samples, while genotype 4 samples were slightly underestimated. For the HPS/CTM assay, a significant underestimation of the HCV RNA concentrations of genotypes 2a/c, 3, 4, and 5 was observed. For the bDNA assay, a constant lower quantification of genotypes 1 to 3 was detected.
منابع مشابه
The Relationship between Hepatitis C Genotypes and Viral Load: a study on hepatitis C patients in Kerman, Iran using Real-time PCR
Abstract Background: Distribution of hepatitis C virus genotypes varies geographically and can be associated with clinical aspects. The virus has six major genotypes and eleven sub-genotypes. According to the recent studies, in hepatitis C patients, treatment duration and ribavirin dosage should be determined based on the type of virus genotype. Be...
متن کاملPERFORMANCE OF THE ABBOTT m2000SP/m2000RT REAL-TIME POLYMERASE CHAIN REACTION ASSAY FOR HEPATITIS C VIRUS RNA QUANTIFICATION
Quantification of hepatitis C virus (HCV) RNA is essential for the everyday management of chronic hepatitis C therapy. " Real-time " polymerase chain reaction (PCR) techniques are potentially more sensitive than classical PCR techniques, are not prone to carryover contamination, and have a consistently wider dynamic range of quantification. Thus they are rapidly replacing other technologies for...
متن کاملPerformance of the Abbott real-time PCR assay using m2000sp and m2000rt for hepatitis C virus RNA quantification.
Quantification of hepatitis C virus (HCV) RNA is essential for the everyday management of chronic hepatitis C therapy. "Real-time" PCR techniques are potentially more sensitive than classical PCR techniques, are not prone to carryover contamination, and have a consistently wider dynamic range of quantification. Thus, they are rapidly replacing other technologies for routine quantification of HC...
متن کاملتعیین کمی بار ویروسی هپاتیت C با استفاده از روش Real-Time PCR In-House در بیماران آلوده به هپاتیت C در شهرستان خرم آباد
Background : Molecular diagnostic methods are among major tools in management of hepatitis C virus (HCV) in infected patients. Many studies have shown that viral load is associated with stage of infection and response to treatment. Therefore, the evaluation and quantification of viral load is very important. The goal of this study is implementation of inexpensive, yet accurate method for quanti...
متن کاملComparison of the AdvanSure HBV real-time PCR test with three other HBV DNA quantification assays.
BACKGROUND We compared the AdvanSure hepatitis B virus real-time polymerase chain reaction (AdvanSure HBV) kit with three other HBV DNA quantification assays and evaluated its performance. METHODS The AdvanSure HBV real-time PCR assay was compared with the Abbott RealTime HBV Quantification Kit, the COBAS TaqMan HBV Test, and the VERSANT HBV branched DNA 3.0 assay. The precision, linearity, a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of clinical microbiology
دوره 44 3 شماره
صفحات -
تاریخ انتشار 2006