Equivalency testing of TTC Tergitol 7 agar (ISO 9308-1:2000) with five culture media for the detection of E. coli in water samples in Greece.
نویسندگان
چکیده
In this study ten laboratories in Greece compared the performance of reference method TTC Tergitol 7 Agar (with the additional test of beta-glucuronidase production) with five alternative methods, to detect E. coli in water, in line with European Water Directive recommendations. The samples were prepared by spiking drinking water with sewage effluent following a standard protocol. Chlorinated and non-chlorinated samples were used. The statistical analysis was based on the mean relative difference of confirmed counts and was performed in line with ISO 17994. The results showed that in total, three of the alternative methods (Chromocult Coliform agar, Membrane Lauryl Sulfate agar and Trypton Bilex-glucuronidase medium) were not different from TTC Tergitol 7 agar (TTC Tergitol 7 agar vs Chromocult Coliform agar, 294 samples, mean RD% 5.55; vs MLSA, 302 samples, mean RD% 1; vs TBX, 297 samples, mean RD% -2.78). The other two alternative methods (Membrane Faecal coliform medium and Colilert 18/ Quantitray) gave significantly higher counts than TTC Tergitol 7 agar (TTC Tergitol 7 agar vs MFc, 303 samples, mean RD% 8.81; vs Colilert-18/Quantitray, 76 samples, mean RD% 18.91). In other words, the alternative methods generated performance that was as reliable as, or even better than, the reference method. This study will help laboratories in Greece overcome culture and counting problems deriving from the EU reference method for E. coli counts in water samples.
منابع مشابه
Use of the ISO 9308-1 procedure for the detection of E. coil in water utilizing two incubation temperatures and two confirmation procedures and comparison with defined substrate technology.
Disinfected and non-disinfected samples have been used to determine the accuracy of the ISO procedure (ISO 9308-1) for detection of E. coli in drinking water. Samples were analysed using the ISO procedure at both 36 and 44 degrees C and using the defined substrate technology method Colilert-18/Quanti-Tray (Colilert-18). Utilizing the confirmation procedure described in ISO 9308-1, large numbers...
متن کاملA comparison of the International Standards Organisation reference method for the detection of coliforms and Escherichia coli in water with a defined substrate procedure.
AIMS This study investigated the use of the International Standards Organisation (ISO) procedure for the comparison of microbiological methods. Using this procedure the ISO reference procedure for the detection of coliforms and Escherichia coli in water was compared with a defined substrate method (ColilertTM). METHODS AND RESULTS A total of 20 laboratories from 13 European countries compared...
متن کاملComparison of thermotolerant coliforms and Escherichia coli densities in freshwater bodies
Fecal bacterial indicator analyses have been widely used for monitoring the water quality. This study was designed to determine the ratio between the density of Escherichia coli and other Thermotolerant Coliforms (TtC) bacteria from freshwater samples collected for a two-year period of monitoring. TtC were enumerated by membrane filtration on mFC agar. E. coli enumeration was done by two method...
متن کاملComparison of Colilert-18 with miniaturised most probable number method for monitoring of Escherichia coli in bathing water.
The purpose of this equivalence study was to compare an alternative method, Colilert-18 Quanti-Tray (ISO 9308-2) with the European bathing water directive (2006/7/EC) reference method, the miniaturised most probable number (MMPN) method (ISO 9308-3), for the analysis of Escherichia coli. Six laboratories analysed a total of 263 bathing water samples in Finland. The comparison was carried out ac...
متن کاملIsolation of lytic bacteriophages against pathogenic Escherichia coli strains in poultry in the northwest of Iran
In this study, 90 internal organ samples of poultry with symptoms of colibacillosis were obtained from Maragheh poultry farms in East Azerbaijan, Iran. In total, 70 bacterial isolates were confirmed as Escherichia coli (E. coli) strains using standard biochemical tests, and antibiotic sensitivity was determined by the disk diffusion method. Antibiotics used in this study included ampicillin, pe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Water science and technology : a journal of the International Association on Water Pollution Research
دوره 61 1 شماره
صفحات -
تاریخ انتشار 2010