Surface microtopography design and manufacturing through topography descriptors: an application to prosthetic implant surfaces
نویسندگان
چکیده
A surface microtopography design and manufacturing methodology is presented that handles the intrinsic geometrical complexity of a surface microtopography by introducing topography descriptors. The concept of topography descriptor is a generalization originating from known techniques of three-dimensional surface topography analysis. Topography descriptors may be seen as transfer functions that can be defined to map selected microtopographic properties of a surface to scalar values that can be used for quantitative evaluation and/or comparison purposes; they are intended to provide a compact representation of otherwise complex morphologic information by selecting only the information which is deemed relevant to a specific function, context, or application domain. When properly defined, topography descriptors can help in the assessment of the functional performance of different surface microtopographies; also, they can provide support to the development of virtual microtopography models specialized in the replication of specific aspects of a surface morphology, which may be useful, for example, to investigate the relationships between surface morphology and function, or between surface morphology and manufacturing process parameters for surface generation. In this work, the proposed methodology is applied to the design of the microtopography of the coated surface of a prosthetic implant. Topography descriptors are identified which are suitable to describe microtopographic properties related to a specific functional property: the bone-implant interfacial shear strength. Such topography descriptors are evaluated over real specimens, obtained by Vacuum Plasma Spray deposition of porous titanium or fluorinated hydroxyapatite over a titanium alloy substrate, in order to assess their relationship with functional performance. Then, a dedicated procedural model, embedding Vacuum Plasma Spray simulation algorithms, is developed to generate virtual microtopographies with the intent of understanding the relationships between topography descriptors and manufacturing process parameters, for process planning purposes. The developed models and obtained results are discussed and their suitability as tools for surface topography design and manufacturing is assessed. q 2005 Elsevier Ltd. All rights reserved.
منابع مشابه
Effect of implant surface microtopography by hydroxyapatite grit-blasting on adhesion, proliferation, and differentiation of osteoblast-like cell line, MG-63
With regards to their biological and physiochemical properties, titanium-based biomaterials have been successfully used in orthopaedic, dental and maxillo-facial surgery mainly as endosseous implants. The early osseointegration of titanium dental implants is an important factor for their clinical success. The implant loading to bone is influenced by various factors, including surface chemistry,...
متن کاملActin cytoskeletal organization in human osteoblasts grown on different dental titanium implant surfaces.
The understanding of the cellular basis of osteoblastic cell-biomaterial interaction is crucial to the analysis of the mechanism of osseointegration. Cell adhesion is a complex process that is dependent on the cell types and on the surface microtopography and chemistry of the substrate. We have studied the role of microtopography in modulating cell adhesion, in vitro, using a human osteoblastic...
متن کاملImmediate Placement of Dental Implants: a Safe a Predictable Treatment Option
Micro structure is the microscopic surface topography of an implant. In simple terms, is it smooth or is it rough. The rougher the surface, the better. A roughened surface is directly associated with higher implant survival rates (Figure 1) [2]. Micro structure has a direct effect on the osseointegrative process and therefore most important in the long term stability of an implant after healing...
متن کاملCAD-CAM implant-supported fixed complete dental prosthesis with titanium milled molars: A clinical report.
Implant-supported fixed complete dental prostheses have been associated with a high implant success rate in long-term studies. However, they have also been associated with a high frequency of prosthetic complications. The most frequent and primary prosthetic complication has been the fracture or wear of the occlusal surface of acrylic resin teeth that are typically attached to a metal framework...
متن کاملAbutment fracture and the technique Used to Remove the fracture portion of the Abutmet: Case Report
Abstract This clinical report presents a case of abutment fracture, due to occlusal overload, occurred with an implant-supported restoration on right mandibular first molar of a female patient. After 6 months of prosthetic reconstruction implants, the patient returned to the clinic due to the loss of implant crown. The fractured fragment of the abutment with the screw protec...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Computer-Aided Design
دوره 37 شماره
صفحات -
تاریخ انتشار 2005