Solid-phase microextraction as a novel air sampling technology for improved, GC-olfactometry-based assessment of livestock odors.

نویسندگان

  • Jacek A Koziel
  • Lingshuang Cai
  • Donald W Wright
  • Steven J Hoff
چکیده

Air sampling and characterization of odorous livestock gases is one of the most challenging analytical tasks. This is because of low concentrations, physicochemical properties, and problems with sample recoveries for typical odorants. Livestock operations emit a very complex mixture of volatile organic compounds (VOCs) and other gases. Many of these gases are odorous. Relatively little is known about the link between characteristic VOCs/gases and, specifically, about the impact of characteristic odorants downwind from sources. In this research, solid-phase microextraction (SPME) is used for field air sampling of odors downwind from swine and beef cattle operations. Sampling time ranges from 20 min to 1 h. Samples are analyzed using a commercial gas chromatography-mass spectrometry-olfactometry system. Odor profiling efforts are directed at odorant prioritization, with respect to distance from the source. The results indicate the odor downwind is increasingly defined by a smaller number of high-priority odorants. These "character defining" odorants appear to be dominated by compounds of relatively low volatility, high molecular weight, and high polarity. In particular, p-cresol alone appears to carry much of the overall odor impact for swine and beef cattle operations. Of particular interest is the character-defining odor impact of p-cresol as far as 16 km downwind of the nearest beef cattle feedlot. The findings are highly relevant to scientists and engineers working on improved air sampling and analysis protocols and on improved technologies for odor abatement. More research evaluating the use of p-cresol and a few other key odorants as a surrogate for overall odor dispersion modeling is warranted.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Characterization of livestock odors using steel plates, solid-phase microextraction, and multidimensional gas chromatography-mass spectrometry-olfactometry.

Livestock operations are associated with emissions of odor, gases, and particulate matter (PM). Livestock odor characterization is one of the most challenging analytical tasks. This is because odor-causing gases are often present at very low concentrations in a complex matrix of less important or irrelevant gases. The objective of this project was to develop a set of characteristic reference od...

متن کامل

Characterization of volatile organic compounds and odors by in-vivo sampling of beef cattle rumen gas, by solid-phase microextraction, and gas chromatography-mass spectrometry-olfactometry.

Volatile organic compounds (VOCs) and odors in cattle rumen gas have been characterized by in-vivo headspace sampling by solid-phase microextraction (SPME) and analysis by gas chromatography-mass spectrometry-olfactometry (GC-MS-O). A novel device enabling headspace SPME (HS-SPME) sampling through a cannula was designed, refined, and used to collect rumen gas samples from steers. A Carboxen-pol...

متن کامل

Determination of major aroma impact compounds in fermented cucumbers by solid-phase microextraction--gas chromatography--mass spectrometry--olfactometry detection.

Purge-and-trap, solid-phase extraction, and solid-phase microextraction-gas chromatography-mass spectrometry (SPME-GC-MS) sample preparation techniques for the analysis of odor impact chemicals in fermented cucumber brine are compared. SPME-GC-MS is coupled with detection frequency olfactometry experiments to determine key impact odor compounds in the brine. The most potent odorants that define...

متن کامل

Recent Advances in Microextraction Methods for Sampling and Analysis of Volatile Organic Compounds in Air: A Review

Human exposures to volatile organic compounds (VOCs) are associated with a wide range of health problems. Due to these adverse effects of VOCs on the human health, determination of trace levels of VOCs is very important for accurate assessment of indoor and outdoor exposure. Solid phase microextraction (SPME), needle trap device (NTD) and hollow fiber- liquid phase microextraction (HF-LPME) are...

متن کامل

Assessment of a Two-Stage Wood Chip-Based Biofilter Using Solid-Phase Microextraction and Gas Chromatography-Mass Spectrometry-Olfactometry

Abstract. A mobile pilot-scale biofilter testing laboratory, which consisted of oneand two-stage biofilter reactor barrels, was developed where two types of wood chips (western cedar and hard wood) were examined to treat odor emissions from a deep-pit swine finishing facility in central Iowa. The biofilters were operated continuously from July 20 to October 17, 2007 at different air flow rates ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of chromatographic science

دوره 44 7  شماره 

صفحات  -

تاریخ انتشار 2006