The high mass transport caused by ultrasonic radiation in the preconcentration of trace metal species in anodic stripping voltammetry (ASV), leads to an order of magnitude enhancement in sensitivity. A Nafion-coated mercury thin-film working electrode is placed in a specially designed small-volume sonovoltammetric cell. The preparation and curing procedure for the Nafion film on a glassy carbon electrode substrate as well as ultrasound-enhanced mercury deposition through the Nafion film are optimized. The resulting electrode assembly is stable under ultrasonic irradiation. Optical microscopy observations show the formation of closely spaced mercury droplets of micrometer dimensions under the Nafion film. The performance characteristics of ultrasound-enhanced ASV at the Nafion-coated mercury thin-film electrode are studied in detail. The detection limit obtained for lead and cadmium test species is 3 × 10-11 M (30 s preconcentration in the presence of ultrasound). A relative standard deviation of 1.2% is obtained for repetitive determinations of 10 nM Cd2+ (n ) 9).
منابع مشابه
Poly(ester sulphonic acid) coated mercury thin film electrodes: characterization and application in batch injection analysis stripping voltammetry of heavy metal ions.
Mercury-thin film electrodes coated with a thin film of poly(ester sulphonic acid) (PESA) have been investigated for application in the analysis of trace heavy metals by square wave anodic stripping voltammetry using the batch injection analysis (BIA) technique. Different polymer dispersion concentrations in water/acetone mixed solvent are investigated and are characterised by electrochemical i...
متن کاملLinear sweep anodic stripping voltammetry of heavy metals from nitrogen doped tetrahedral amorphous carbon thin films
Nitrogen doped tetrahedral amorphous carbon (ta-C:N) thin films were deposited on p-Si (1 11) substrates (1×10−3 to 6×10−3 cm) by a filtered cathodic vacuum arc technique with different nitrogen flow rates (3 and 20 sccm). The ta-C:N film coated samples were used as working electrodes to detect trace heavy metals such as zinc (Zn), lead (Pb), copper (Cu) and mercury (Hg) by using linear sweep a...
متن کاملSensors 2001, 1, 206-214
The electrochemical polymerization of 2-aminobenzenesulfonic acid with and without aniline has been carried by cyclic potencial sweep in sulfuric acid solution at the glassy carbon electrode. The polymer and copolymer formed have been characterized voltammetrically. The sulfonated polyaniline coated mercury thin-film electrodes have been evaluated for use with anodic stripping voltammetry. The ...
متن کاملNafion-coated bismuth film and nafion-coated mercury film electrodes for anodic stripping voltammetry combined on-line with ICP-mass spectrometry.
Nafion-coated bismuth film electrodes (NCBFEs) and Nafion-coated mercury film electrodes (NCMFEs) were used to electrochemically preconcentrate metal analytes for subsequent analysis by inductively coupled plasma-mass spectrometry (ICP-MS). Either type of electrodes is part of a thin-layer electrochemical flow cell that is positioned upstream of a microconcentric nebulizer for the ICP-MS. Perfo...
متن کاملLabVIEW-based sequential-injection analysis system for the determination of trace metals by square-wave anodic and adsorptive stripping voltammetry on mercury-film electrodes
The development of a dedicated automated sequential-injection analysis apparatus for anodic stripping voltammetry (ASV) and adsorptive stripping voltammetry (AdSV) is reported. The instrument comprised a peristaltic pump, a multiposition selector valve and a home-made potentiostat and used a mercury-film electrode as the working electrodes in a thin-layer electrochemical detector. Programming o...
متن کامل