The Influence of Storage Temperature on the Antibiotic Release of Vancomycin-Loaded Polymethylmethacrylate
نویسندگان
چکیده
Periprosthetic joint infection is devastating and increases medical expenditure and socioeconomic burden. Antibiotic-loaded cement spacer is useful in the interim period before the reimplantation surgery. Prefabricated antibiotic-loaded cement spacers can decrease operation time but have been limitedly used clinically. In the literature, there is no clear recommendation on the storage temperature for the prefabricated cement spacers. We used an in vitro model to analyze whether the storage temperature at 25°C, 4°C, or -20°C for 2 weeks or 3 months could affect the release of vancomycin from the cement. We found that the storage temperature and time had no significant effects on the pattern and amount of vancomycin release. The patterns of vancomycin release from the cement stored at different temperatures were similar with an abrupt release in the first 3 days and steadily declined in the following period. This study provides a preliminary result to justify the storage of fabricating antibiotic-loaded cement spacer sterilely packed at room temperature. Further studies to examine the effects of storage temperature on the mechanical strength and the release pattern of other antibiotics should be done to provide more evidence to support the clinical use of prefabricated ready-to-use antibiotic-loaded cement spacer.
منابع مشابه
Implants modified with polymeric nanofibers coating containing the antibiotic vancomycin
Objective(S): Implant-related infections are disastrous complications in the clinic. One recent strategy to reduce the rate of infection is using the bioactive coating with an antibiotic. The purpose of these bioactive surfaces is to prevent bacterial adhesion to the implant and, consequently, the development of biofilm. In this study, vancomycin-loaded polymeric coating on imp...
متن کاملIn vivo and in vitro studies of antibiotic release from and bacterial growth inhibition by antibiotic-impregnated polymethylmethacrylate hip spacers.
The antimicrobial properties and the elution characteristics of gentamicin-vancomycin-loaded hip spacers were studied in vivo and in vitro. Vancomycin elution was greater than gentamicin elution. The antibiotic concentrations in vivo were less than those in vitro. Not dependent on implantation duration, growth inhibition by spacers in vitro was observed for 2 weeks. The reason for protracted wo...
متن کاملIn vitro evaluation of antibiotic diffusion from antibiotic-impregnated biodegradable beads and polymethylmethacrylate beads.
Antibiotic-impregnated beads are used in the dead bone space following debridement surgery to deliver local, high concentrations of antibiotics. Polymethylmethacrylate (PMMA), 2,000-molecular-weight (MW) polylactic acid (PLA), Poly(DL-lactide)-coglycolide (PL:CG; 90:10, 80:20, and 70:30), and the combination 2,000-MW PLA-70:20 PL:CG were individually mixed with clindamycin, tobramycin, or vanco...
متن کاملRelease of Gentamicin and Vancomycin from Preformed Spacers in Infected Total Hip Arthroplasties: Measurement of Concentrations and Inhibitory Activity in Patients' Drainage Fluids and Serum
Gentamicin (G) and vancomycin (V) concentrations in drainage fluids obtained from patients during the first 24 hours after implantation of antibiotic-loaded polymethylmethacrylate (PMMA) spacers in two-stage revision of infected total hip arthroplasty were studied. The inhibitory activity of drainage fluids against different multiresistant clinical isolates was investigated as well. Seven hips ...
متن کاملResidual gentamicin-release from antibiotic-loaded polymethylmethacrylate beads after 5 years of implantation.
In infected joint arthroplasty, high local levels of antibiotics are achieved through temporary implantation of non-biodegradable gentamicin-loaded polymethylmethacrylate beads. Despite their antibiotic release, these beads act as a biomaterial surface to which bacteria preferentially adhere, grow and potentially develop antibiotic resistance. In routine clinical practice, these beads are remov...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2013 شماره
صفحات -
تاریخ انتشار 2013