Predictors of event-free survival after repeat intracoronary procedure for in-stent restenosis; study with angiographic and intravascular ultrasound imaging.
نویسندگان
چکیده
AIMS Lumen enlargement during repeat percutaneous coronary intervention for in-stent restenosis has been shown to be the result of both stent over-expansion and decrease in neointimal tissue. How these two different mechanisms of action may influence outcome and target lesion revascularization after repeat intervention for in-stent restenosis is unclear. METHODS Intravascular ultrasound guided repeat intervention for in-stent restenosis was carried out either with balloon angioplasty, or with a combination of rotational atherectomy plus balloon angioplasty. Clinical follow-up at 1 year, including death, myocardial infarction, or need for revascularization, was obtained. RESULTS Seventy patients were included in this study; 40 were treated by balloon alone, and 30 by combination of rotational atherectomy plus balloon. Event-free survival probability was 76+/-5%. The mechanism of lumen enlargement, be it stent over-expansion or tissue removal, had no influence on long-term clinical evolution. The only independent predictor was the minimal lumen cross-sectional area at the end of the procedure, the larger the lumen cross-sectional area, the higher the event-free probability. The cut-off point of the lumen cross-sectional area was set at 4.7 mm(2)by discriminant analysis. Event-free survival was 69+/-15% in patients with <4.7 mm(2)lumen cross-sectional area and 91+/-8% in patients with >4.7 mm(2)lumen cross-sectional area (P=0. 008). CONCLUSIONS This study showed that the only independent predictor of late clinical outcome after percutaneous re-intervention for in-stent restenosis was final lumen size, no matter which means were used to achieve it.
منابع مشابه
Angiographic and intravascular ultrasound predictors of in-stent restenosis.
OBJECTIVES This study was performed to determine predictors of in-stent restenosis from a high volume, single-center practice. BACKGROUND Intracoronary stents have been shown to reduce the restenosis rate as compared with balloon angioplasty, but in-stent restenosis continues to be an important clinical problem. METHODS Between April 1993 and March 1997, 1,706 patients with 2,343 lesions we...
متن کاملIntravascular ultrasound predictors of angiographic restenosis after sirolimus-eluting stent implantation.
AIMS In many countries, drug-eluting stent implantation is the dominant interventional strategy. We evaluated the clinical, angiographic, procedural, and intravascular ultrasound (IVUS) predictors of angiographic restenosis after sirolimus-eluting stent (SES) implantation. METHODS AND RESULTS SES implantation was successfully performed in 550 patients with 670 native coronary lesions. Six-mon...
متن کاملOverview of Intracoronary Brachytherapy for in-Stent Restenosis of a Drug-Eluting Stent
Percutaneous coronary intervention with stenting is considered recently as the most common procedure for the treatment of symptomatic coronary. The article reviewed 41 studies published during 1997-2019 on intracoronary brachytherapy for in-stent restenosis of a drug-eluting stent. Intracoronary radiation therapy was finally confirmed in the setting of in-stent restenosis using as adjunctive th...
متن کاملIn-stent restenosis: long-term outcome and predictors of subsequent target lesion revascularization after repeat balloon angioplasty.
OBJECTIVES We sought to evaluate the long-term clinical outcome of patients undergoing successful balloon angioplasty for in-stent restenosis, and to determine correlates of the need for subsequent target lesion revascularization (TLR). BACKGROUND In-stent restenosis can be safely treated by repeat percutaneous intervention. Reported subsequent TLR rates have varied from 20% to 80% and seem r...
متن کاملSafety, Efficacy and Clinical Outcome of Direct Stent Implantation
Conventional methods of stenting require predilatation, which potentially increase vessel wall injury and cost of the procedure. In this study, the safety and efficacy of direct AVE-S7 (Medtronic-USA) stent placement were evaluated in 100 patients. Quantitative coronary angiography was performed at the baseline and post-stent. Clinical follow-up was done up to 9 months. In 100 patients (76 male...