Calibration of the ATLAS Muon Spectrometer Precision Chambers for Initial LHC Beam Collisions

نویسنده

  • Haijun Yang
چکیده

ATLAS is a general purpose experiment at the Large Hadron Collider (LHC) at CERN which began operation in September, 2009. ATLAS has a large muon spectrometer which is designed to measure muon momentum with a resolution ranging from 3% at 100 GeV/c to 10% at 1 TeV for a pseudorapidity range of 0-2.7. In this paper, we describe the derivation and validation of calibration constants for the Monitored Drift Tubes (MDTs) in the ATLAS muon spectrometer for use with initial LHC collisions. At LHC start-up, the luminosity was not sufficient for ordinary calibrations with collision muons, and so alternative methods were developed. The time-to-space (RT) functions were obtained from the University of Michigan gas monitor chamber and the (t0s) were derived from LHC beamsplash events from 2009 and 2010. We have validated these calibration constants by performing muon track reconstruction using 900 GeV collision data from December, 2009 and 7 TeV data from 2010. We find that these calibration constants yield an MDT chamber hit resolution of 142 μm and a residual width of 91 μm.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Gas Monitor Chamber Calibration Program for the ATLAS Muon Spectrometer Precision Chambers

The ATLAS Muon Spectrometer is designed to measure the momentum of muons with a resolution of dp/p = 3% and 10 % at beam energies of 100 GeV and 1 TeV respectively. To do this, the spectrometer employs 355,000 Monitored Drift Tubes (MDTs) in 1200 Chambers. Calibration (RT) functions convert drift time measurements into tube-centered impact parameters for track segment reconstruction. RT functio...

متن کامل

A Cosmic Ray Measurement Facility for ATLAS Muon Chambers

Monitored Drift Tube (MDT) chambers will constitute the large majority of precision detectors in the Muon Spectrometer of the ATLAS experiment at the Large Hadron Collider at CERN. For commissioning and calibration of MDT chambers, a Cosmic Ray Measurement Facility is in operation at Munich University. The objectives of this facility are to test the chambers and on-chamber electronics, to map t...

متن کامل

Tracking and Level-1 triggering in the forward region of the ATLAS Muon Spectrometer at sLHC

In the endcap region of the ATLAS Muon Spectrometer (η > 1) precision tracking and Level-1 triggering are performed by different types of chambers. Monitored Drift Tube chambers (MDT) and Cathode Strip Chambers (CSC) are used for precision tracking, while Thin Gap Chambers (TGC) form the Level-1 muon trigger, selecting muons with high transverse momentum (pT ). When by 2018 the LHC peak luminos...

متن کامل

The ALICE muon trigger system: cosmic ray commissioning and first beam-induced events

The ALICE experiment is designed to study strongly interacting nuclear matter which will be produced in heavy ion collisions at the Large Hadron Collider (LHC). The muon spectrometer of the ALICE experiment is equipped with a trigger system based on resistive plate chambers. A commissioning phase was started in 2008 with the detection of cosmic rays and induced particles of the first beam injec...

متن کامل

Commissioning and performance of the ATLAS Inner Detector with the first beam and cosmic data

The ATLAS experiment at the CERN Large Hadron Collider (LHC) started data-taking in Autumn 2008 with the inauguration of the LHC. The Inner Detector is a tracking system for charged particles based on three technologies: silicon pixels, silicon microstrips and drift tubes. The detector was commissioned and calibrated in the ATLAS cavern. Cosmic muons data are used for timing the different compo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -