Improved protamine-sensitive membrane electrode for monitoring heparin concentrations in whole blood via protamine titration.

نویسندگان

  • N Ramamurthy
  • N Baliga
  • J A Wahr
  • U Schaller
  • V C Yang
  • M E Meyerhoff
چکیده

An improved protamine-sensitive electrode based on a polymeric membrane doped with the charged ion exchanger dinonylnaphthalenesulfonate (DNNS) is used for monitoring heparin concentrations in whole blood. The electrode exhibits significant nonequilibrium potentiometric response to polycationic protamine over the concentration range of 0.5-20 mg/L in undiluted whole-blood samples. The sensor can serve as a simple end point detector for the determination of heparin via potentiometric titrations with protamine. Whole-blood heparin concentrations determined by the electrode method (n > or = 157) correlate well with other protamine titration-based methods, including the commercial Hepcon HMS assay (r = 0.934) and a previously reported potentiometric heparin sensor-based method (r = 0.973). Reasonable correlation was also found with a commercial chromogenic anti-Xa heparin assay (r = 0.891) with corresponding plasma samples and appropriate correction for whole-blood hematocrit levels. Whereas a significant positive bias (0.62 kU/L; P < 0.001) is observed between the anti-Xa assay and the protamine sensor methods, insignificant bias is observed between the protamine sensor and the Hepcon HMS tests (0.08 kU/L; P = 0.02). The possibility of fully automating these titrations offers a potentially simple, inexpensive, and accurate method for monitoring heparin concentrations in whole blood.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Enhanced sensitivity electrochemical assay of low-molecular-weight heparins using rotating polyion-sensitive membrane electrodes.

Use of a novel rotating polycation-sensitive polymer membrane electrode yields sensors that can serve as simple potentiometric titration endpoint detectors for the determination of three FDA approved low-molecular-weight heparin (LMWH) anticoagulant drugs (Fragmin, Normiflo, and Lovenox). The rotating electrode configuration dramatically improves the reproducibility and increases the sensitivit...

متن کامل

Flash chronopotentiometric sensing of the polyions protamine and heparin at ion-selective membranes.

We report here on a highly sensitive and rapid detection technique, multipulse flash chronopotentiometry, for the anticoagulant polyion heparin and its antidote protamine. The technique is based on a localized titration of the polyions at the surface of an appropriately formulated polymeric ion-selective membrane devoid of ion exchange properties to prohibit spontaneous extraction processes. A ...

متن کامل

Heparin monitoring during cardiopulmonary bypass.

Three procedures have been compared for monitoring heparin in patients undergoing cardiopulmonary bypass: (1) activated clotting time (ACT) (2) protamine titration, and (3) fluorometric substrate assay. The ACT monitors the degree of anticoagulation. It is easy to perform and is relatively inexpensive, however, it does not correlate well with heparin levels and may not accurately predict the pr...

متن کامل

Neutralization of Heparin Using a Protamine Titration Assay and the Activated Clotting Time Test

_____________ _ (J. Extra-Corpor. Techno/. 19 [3] p. 358-364 Fall1987, 16 ref.) Many of the clinical protocols currently used to calculate the protamine (Pr) dosage for heparin neutralization following cardiopulmonary bypass (CPB) utilize an empirical Pr to heparin ratio. Pr titration, though a proven method of dosage calculation, is inherently tedious and thus not routinely used in the operati...

متن کامل

Effect of RBCs on the activation of human complement by heparin-protamine complexes.

Complement activation on red cells by heparin-protamine complexes was studied by using whole human serum. C3 bound to red cells was measured by radiolabeled monoclonal antibody to C3, and fluid-phase C5a was determined by radioimmunoassay. Heparin and protamine in clinically relevant concentrations caused the binding of C3 to red cell membranes, and the measurement of C3 binding provided a sens...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 44 3  شماره 

صفحات  -

تاریخ انتشار 1998