Reactive current control through SVC for load power factor correction
نویسندگان
چکیده
This paper discusses a new technique for controlling SVCs (Fixed Capacitor–Thyristor Controlled Reactor) in power systems with the aim of canceling the reactive current component of the load. A complete model of the SVC with its control circuit is set up and simulated in the EMTDC program. The generated harmonics from the proposed SVC controller are considered to design simple tuned filters to cancel the undesirable harmonic components. The effect of these filters is considered as well in the SVC control design, so that the reactive current component absorbed by the combination of the load, SVC, and filters is eliminated. The proposed control technique is compared with respect to a standard PI-based SVC controller. © 2005 Elsevier B.V. All rights reserved.
منابع مشابه
A New Approach for Reactive Power Control of Single Phase Transformerless Inverter to Modify Power Quality in Stand Alone Micro-Grids with Current Leakage Elimination
Nowadays there has been an increasing interest in transformerless inverter for grid-connected photovoltaic (PV) system due to low cost, high efficiency and light weight. One of the reasons describe the grid behavior is capability of reactive power control by inverter. According to the standard VDE-AR-N 4105, grid-tied PV inverter of power rating below 3.68KVA, should attain power factor (PF) fr...
متن کاملActive Power Filter Design by a Novel Approach of Multi-Objective Optimization
This paper presents an innovative active power filter design method to simultaneously compensate the current harmonics and reactive power of a nonlinear load. The power filter integrates a passive power filter which is a RL low-pass filter placed in series with the load, and an active power filter which comprises an RL in series with an IGBT based voltage source converter. The filter is assumed...
متن کاملThe Novel Control Method for Photovoltaic Converter to the National Grid
In this paper, a novel control method for photovoltaic converter connection to the national gridis presented, so in addition to the injection control by solar arrays to the grid, this method cancompensate reactive power and harmonics in the load current. The system will be connected inparallel between the grid and load. The proposed system supplies all load power consumption(including active po...
متن کاملImproving the performance of UPQC under unbalanced and distortional load conditions: A new control method
This paper presents a new control method for a three-phase four-wire Unified Power Quality Conditioner (UPQC) to deal with the problems of power quality under distortional and unbalanced load conditions. The proposed control approach is the combination of instantaneous power theory and Synchronous Reference Frame (SRF) theory which is optimized by using a self-tuning filter (STF) and without us...
متن کاملA Comparison between SVC and STATCOM in Flicker Mitigation of Electric Arc Furnace using Practical Recorded Data
Electric arc furnace (EAF) is one of the largest loads in electric power systems. It is highly time varying and nonlinear. Its reactive power variations cause voltage fluctuations in nearby system which is known as flicker. On the other hand the nonlinear voltage-current characteristic causes strong voltage and current harmonics in EAF. To this end Flexible AC Transmission Systems (FACTS) techn...
متن کامل