Autofocus and two-fold astigmatism correction in HAADF-STEM
نویسندگان
چکیده
A new simultaneous autofocus and two-fold astigmatism correction method is proposed for High Angle Annular Dark Field Scanning Transmission Electron Microscopy (HAADF-STEM). The method makes use of a modification of an image variance, which has already been used before as an image quality measure for different types of microscopy. In this paper we describe numerical simulations based on a classical HAADF-STEM linear image formation model showing that the modified variance reaches it’s maximum for Scherzer focus and zero astigmatism. In order to find this maximum in a three-parameter space we employ the well-known Nelder-Mead simplex optimization algorithm. The method is implemented and tested on a FEI Tecnai F20. It successfully finds the optimal defocus and zero astigmatism with the time and accuracy, compared with the human operator. The method is iterative, and finding the optimal defocus and zero astigmatism requires obtaining typically 20-50 images.
منابع مشابه
An auto-tuning method for focusing and astigmatism correction in HAADF-STEM, based on the image contrast transfer function.
An auto-tuning method for high-angle annular detector dark field scanning transmission electron microscopy (HAADF-STEM) is proposed which corrects the defocus to the optimum Scherzer focus and compensates the astigmatism. Because the method is based on the image contrast transfer function formulated for the HAADF-STEM, the defocus and the astigmatism are accurately measured from input of two di...
متن کاملDerivative-free optimization for autofocus and astigmatism correction in electron microscopy
A simultaneous autofocus and twofold astigmatism correction method for electron microscopy is described. The method uses derivative-free optimization in order to find a global optimum of an image variance, which is an image quality measure. The Nelder-Mead simplex method and the Powell interpolation-based trust-region method are discussed and compared for an application running on a scanning tr...
متن کاملGradient-based Sharpness Function
Most autofocus methods are based on a sharpness function which delivers a real-valued estimate of an image quality. In this paper we study an L2−norm gradient-based sharpness function for two-dimensional images (2-D setting). Within this setting we are able to take into account the asymmetry of the optical device objective lens (astigmatism aberration). This study provides a useful extension of...
متن کاملScanning transmission electron microscopy methods for the analysis of nanoparticles.
Here we review the scanning transmission electron microscopy (STEM) characterization technique and STEM imaging methods. We describe applications of STEM for studying inorganic nanoparticles, and other uses of STEM in biological and health sciences and discuss how to interpret STEM results. The STEM imaging mode has certain benefits compared with the broad-beam illumination mode; the main advan...
متن کاملSar Autofocus and Phase Correction Simulation
Both satellite and airborne SAR data is subject to a number of perturbations which stem from various causes and lead to unknown phase chages in the raw data and subsequent imagery which may be defocussed or non-linear. As part of their SAR processing capability, NASoftware offer a combined autofocus with phase correction capability that allows unknown sensor motions to be derived from the recei...
متن کامل