In Vitro Fit and Cementation Resistance of Provisional Crowns for Single Implant-Supported Restorations.
نویسندگان
چکیده
This study aimed to verify marginal fit and the effect of cement film thickness standardization on retention of provisional crowns made with prefabricated acrylic cylinders on abutments, using two temporary luting agents subjected or not to mechanical cycling. Provisional crowns were made from bis-acryl (Luxatemp Fluorescence) or methyl methacrylate (Duralay) resins on acrylic cylinders and marginal fit and cement film thickness were evaluated. For retention evaluation, crowns were cemented with two temporary luting agents: non-eugenol zinc oxide (Tempbond NE) or calcium hydroxide-based (Hydcal) cements and subjected to tensile strength in a universal testing machine. After cleaning, debonded crowns were cemented again, subjected to mechanical cycling and retention was reassessed. The results of marginal fit and cement film thickness were analyzed by Student's t-test while retention of cements before and after mechanical cycling was analyzed using a mixed linear model. Methyl methacrylate crowns presented greater marginal misfit (p=0.001) and occlusal cement film thickness (p=0.003) than the bis-acryl ones. No difference was observed at axial cement film thickness (p=0.606). Resins (p=0.281) did not affect crown retention, but luting agents (p=0.029) and mechanical cycling (p=0.027) showed significant effects. The only significant interaction was mechanical cycling*luting agents, which means that luting agents were differently affected by mechanical cycling (p=0.002). In conclusion, the results showed that bis-acryl resin associated to calcium-hydroxide luting agent provided the best retention and lower cement thickness.
منابع مشابه
Comparison of uniaxial resistance forces of cements used with implant-supported crowns.
PURPOSE Provisional cements are commonly used to facilitate retrievability of cement-retained fixed implant restorations. While the functional life spans of these cements are unpredictable, the relative retentiveness of various permanent and provisional cements between dental alloys and titanium abutments is not well documented. The aim of this study was to compare the uniaxial resistance force...
متن کاملMarginal Fit Metal-Ceramic and In-Ceram Single Crown Cement retained in Implant-supported Abutments.
INTRODUCTION This study evaluated the cervical fit of cemented metal-ceramic and In-Ceram implant-supported crowns, before and after the cementing procedure. MATERIALS AND METHODS Twenty crowns cemented on implant abutments are divided into two groups (n = 10): Group 1 -cemented metal-ceramic crowns and group 2 - cemented In-Ceram crowns. The marginal adaptations before and after cementation ...
متن کاملIn vitro comparative evaluation of mechanical properties of temporary restorative materials used in fixed partial denture
INTRODUCTION Materials used to fabricate provisional restorations can be classified as acrylics or resin composites. Provisional crows can be either prefabricated or custom made. ACRYLICS These materials have been used to fabricate provisional restorations since the 1930s and usually available as powder and liquid. They are the most commonly used materials today for both single-unit and multi...
متن کاملA short-term clinical evaluation of immediately restored maxillary TiOblast single-tooth implants.
PURPOSE The purpose of this study was to evaluate the short-term clinical outcome of single-tooth implants placed in the maxilla and immediately restored using cementless friction-fit temporary crowns. MATERIALS AND METHODS Twenty-five patients consecutively referred to a private specialist practice for the replacement of failing or missing maxillary teeth were treated by means of immediate t...
متن کاملThe Effect of Abutment Surface Roughness on the Retention of Implant-Supported Crowns Cemented with Provisional Luting Cement
Introduction: Surface roughness can increase the retention of castings by ridges and grooves that are microretentive. This study compared the retention of implant-supported crowns when used with 3 different surface roughness abutments and one temporary cement. Methods: Thirty solid abutments (ITI), 4 mm high, were divided into three groups randomly. In the first group, 10 abutments were roughen...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Brazilian dental journal
دوره 26 5 شماره
صفحات -
تاریخ انتشار 2015