Artifact suppression in imaging of myocardial infarction using B1-weighted phased-array combined phase-sensitive inversion recovery.

نویسندگان

  • Peter Kellman
  • Christopher K Dyke
  • Anthony H Aletras
  • Elliot R McVeigh
  • Andrew E Arai
چکیده

Regions of the body with long T1, such as cerebrospinal fluid (CSF), may create ghost artifacts on gadolinium-hyperenhanced images of myocardial infarction when inversion recovery (IR) sequences are used with a segmented acquisition. Oscillations in the transient approach to steady state for regions with long T1 may cause ghosts, with the number of ghosts being equal to the number of segments. B1-weighted phased-array combining provides an inherent degree of ghost artifact suppression because the ghost artifact is weighted less than the desired signal intensity by the coil sensitivity profiles. Example images are shown that illustrate the suppression of CSF ghost artifacts by the use of B1-weighted phased-array combining of multiple receiver coils.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of inversion times on the minimum signal intensity of the contrast agent concentration using inversion recovery t1-weighted fast imaging sequence

  Background :Inversion recovery (IR) pulse sequences can generate T1-weighted images with a different range of inversion time (TI) to suppress or null the signal intensity (SI) for a specified tissue. In this study, we aimed to investigate the effect of TI values on the concentration of the contrast agent, which leads to a minimum signal intensity, using an inversion recovery T1-weighted 3-dim...

متن کامل

Diagnostic performance of T2-weighted CMR for evaluation of acute myocardial injury

Background Edema-sensitive T2-weighted cardiac magnetic resonance (CMR) based on fast spin-echo (FSE) imaging is a useful modality to detect acute myocardial injury. Conventional T2-weighted CMR uses three inversion-recovery (IR) pulses, the first two to null the blood signal, and the last one (STIR) to null fat signal, but suffers from reduced myocardial signal and signal dropout. We compared ...

متن کامل

Imaging of Reperfused Intramyocardial Hemorrhage with Cardiovascular Magnetic Resonance Susceptibility Weighted Imaging (SWI)

PURPOSE To report initial experience with TE-averaged susceptibility weighted imaging (SWI) in normal subjects and acute myocardial infarction (AMI) patients for the detection of intramyocardial hemorrhage (IMH). MATERIALS AND METHODS 15 healthy control and 11 AMI subjects were studied at 1.5T before contrast agent administration with a dark blood double inversion recovery multiple spoiled gr...

متن کامل

Comparison of 1-d and 2-d surface coil arrays for accelerated volume MR imaging using sensitivity encoding

The optimum phased array combined SNR (B1weighted) [5] and SENSE g-factor were computed for various coil geometries and imaging plane orientations based on simulated field maps. Magnetic fields (B1-maps) for each coil were calculated using the Biot-Savart law. The sample noise correlations between coils which are used in calculating the optimum B1-weighted combining and SENSE g-factor [1] were ...

متن کامل

The validity of a free breathing motion corrected phase sensitive inversion recovery sequence in the detection of delayed myocardial enhancement in non-ischemic heart disease

Background Breath-hold (BH) segmented TURBO FLASH (TFL) is currently used as the gold standard technique to evaluate delayed enhancement (DE) of the myocardium, typically with a phase sensitive inversion recovery (PSIR) approach (1). However, many patients are unable to perform adequate breath-holding resulting in poor image quality and limited diagnostic yield. Free breathing (FB) single shot ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 51 2  شماره 

صفحات  -

تاریخ انتشار 2004