Day - to - Day Variation of the Normal Orthogonal Electrocardiogram and Vectoreardiogram

نویسندگان

  • Pio F. POBLETE
  • HUBERT V. PIPBERGER
چکیده

Day-to-day variation of the corrected orthogonial electrocardiogram was investigated in 20 normal subjects. Ten recordings were made in each individual witlh chest electrode positions left unmarked first, after which 10 subjects underwent another series of 10 consecutive daily recordings with marked electrode locations. Mean and maximal day-to-day variations of durations and amplitudes of different deflections of scalar leads as well as variations of directions and magnitudes of several QRS and T spatial vectors have been studied using computer technics for measurement and analysis. Repeat variability in the unmarked recordings was relatively large. For example, the maximum (96%) variability in QRS spatial maximum and in R-wave amplitudes in leads X and Z were, respectively, 0.50, 0.61, and 0.35 mv. Marking of the chest did reduce variability of amplitude and angular measurements by approximately 25%, but even then a substantial variation from day-to-day remained. Relative chaniges in T-xwave amplitude and direction were greater than those of the QRS complex. The results presented can be used as standards to assess ECG changes observed in serial electrocardiography.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Day to day variation in 3 orthogonal lead electrocardiogram parameters after acute myocardial infarction.

Serial 3 orthogonal lead electrocardiograms were recorded on 67 patients with acute myocardial infarction. For each series of electrocardiograms, the day to day changes and the changes with respect to the initial computer measurements of selected ST-T segment amplitudes and vector orientations were investigated. The results indicated that the degree of rotation of ST-T vectors, which correspond...

متن کامل

Day to day and beat to beat variation in normal 3 orthogonal lead electrocardiograms.

Beat to beat and day to day variation in computer calculated electrocardiographic measurements is described on the basis of a study of normal serial 3 orthogonal lead electrocardiograms recorded on 25 patients. The variation of scalar amplitudes and vector orientations was investigated for both the QRS complex and the ST-T segment. The 96 per cent ranges of beat to beat and day to day variation...

متن کامل

Day-to-day variation of the normal orthogonal electrocardiogram and vectorcardiogram.

Day-to-day variation of the corrected orthogonial electrocardiogram was investigated in 20 normal subjects. Ten recordings were made in each individual witlh chest electrode positions left unmarked first, after which 10 subjects underwent another series of 10 consecutive daily recordings with marked electrode locations. Mean and maximal day-to-day variations of durations and amplitudes of diffe...

متن کامل

Day - to - Day Variation of the Normal Orthogonal Electrocardiogram

Day-to-day variation of the corrected orthogonial electrocardiogram was investigated in 20 normal subjects. Ten recordings were made in each individual witlh chest electrode positions left unmarked first, after which 10 subjects underwent another series of 10 consecutive daily recordings with marked electrode locations. Mean and maximal day-to-day variations of durations and amplitudes of diffe...

متن کامل

مقایسه ارزیابی گاوهای هلشتاین برای تولید شیر با استفاده از مدل‌های روز آزمون و 305 روز

A total of 179,460 monthly test-day milk records (thrice a day milking) obtained from 17,946 Iranian Holstein heifers distributed in 287 herds and calved from 1986 to 2001 were used to predict breeding value of animals. Monthly test-day milk production was analysed by applying a covariance function in which the effects of herd-year-season of production (HYSOP), age at test day (covariate), addi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005