PEO-generated Surfaces Support Attachment and Growth of Cells In Vitro with No Additional Benefit for Micro-roughness in Sa (0.2-4 μm).

نویسندگان

  • Ole Jung
  • Ralf Smeets
  • Alexander Kopp
  • Dario Porchetta
  • Philipp Hiester
  • Max Heiland
  • Reinhard E Friedrich
  • Clarissa Precht
  • Henning Hanken
  • Alexander Gröbe
  • Philip Hartjen
چکیده

BACKGROUND/AIM Plasma electrolytic oxidation (PEO), also known as micro-arc oxidation, is a promising electrochemical surface treatment technique for metals which has been used for the generation of various material surfaces and has been the focus of recent biomaterial research. It has been hypothesized that rough PEO surfaces should generally have properties that support cellular attachment and proliferation. However, this has not yet been demonstrated in systematically conducted studies. The present study investigated fibroblast cell proliferation and attachment to ground, electric discharge machining (EDM) and PEO-treated titanium surfaces differing in roughness and porosity. MATERIALS AND METHODS Three surface variants with 'smoother', 'medium-coarse' and 'rough' surface topographies were generated by PEO and EDM on specimens of titanium alloy (with 6 wt% aluminum and 4 wt% vanadium) for comparison with more smoothly ground specimens. The in vitro effects on cellular attachment and proliferation were determined in 2,3-bis-(2-methoxy-4-nitro-5-sulfophenyl)-2H-tetrazolium-5-carboxanilide (XTT), 5-bromo-2'-deoxyuridine (BrdU) and live/dead staining assays with L929 fibroblasts cultivated directly on the metal specimens. Cytocompatibility was determined in accordance with DIN 10993-5/-12 regulations by extract assays. RESULTS Besides cytocompatibility, all PEO specimens exhibited similar biocompatibility and attachment properties, with vital, spindle-shaped adherent cells growing on the surface, regardless of their surface topology. There were no significant differences in cellular proliferation between the different surfaces and negative controls (cells growing in cell-culture plates). DISCUSSION/CONCLUSION With no differences in cellular proliferation and attachment between PEO surfaces with different roughness, we find no evidence to support the notion that rougher PEO surfaces are more favorable for cellular growth of fibroblasts in vitro.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Differential Attachment of Pulmonary Cells on PDMS Substrate with Varied Features

Cancer is now a global concern, and control of the function of cancer cells is recognized as an important challenge. Although many aggressive chemical and radiation methods are in practice to eliminate cancer cells, most imply severe adverse toxic effects on patients. Taking advantage of natural physical differences between cancer and normal cells might benefit the patient with more specific cy...

متن کامل

Differential Attachment of Pulmonary Cells on PDMS Substrate with Varied Features

Cancer is now a global concern, and control of the function of cancer cells is recognized as an important challenge. Although many aggressive chemical and radiation methods are in practice to eliminate cancer cells, most imply severe adverse toxic effects on patients. Taking advantage of natural physical differences between cancer and normal cells might benefit the patient with more specific cy...

متن کامل

Effect of UV-Photofunctionalization on Bioactivity of Titanium to Promote Human Mesenchymal Stem Cells

Background and Aim: The present study introduces photofunctionalization as a technique for tackling biological aging and increasing the bioactivity of titanium. This in-vitro study evaluated the effects of ultraviolet (UVC) light treatment of titanium surfaces with different time-related changes on the behavior and function of human mesenchymal stem cells (MSCs). Materials and Methods: MSCs we...

متن کامل

Influence of Electrolyte Composition and Voltage on the Microstructure and Growth Mechanism of Plasma Electrolytic Oxidation (PEO) Coatings on Tantalum: A Review

Recently, PEO process of tantalum has been developed as a method of producing corrosion-resistant, hard, wear-resistant, and biocompatible as well as having good adhesion coatings. In this review, we present the results of PEO process of tantalum in three main electrolytes. This review tries to measure the effect of electrolyte composition and voltage that were used within PEO procedure on the ...

متن کامل

P-96: Survey of In Vitro Effect of Noscapine on Nitric Oxide Secretion of Human Endometrial Stromal Cell

Background: Noscapine is cough suppressant drug with cell inhibitory effect. It is introduced for anti-cancer treatment. The aim of present study was to determine in vitro noscapine effect on nitric oxide (NO) secretion by human endometrial stromal cells. Materials and Methods: Human endometrial biopsies (n=8) were obtained in sterile condition and were chopped mechanically and digested by enzy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • In vivo

دوره 30 1  شماره 

صفحات  -

تاریخ انتشار 2016