An In Vivo Model of Continuous Infusion of Ultra High Molecular Weight Polyethylene Particles
نویسندگان
چکیده
Introduction: Wear particles from orthopaedic implants have been shown to affect both initial osseointegration and subsequent bone remodeling of total joint replacements (TJRs). Continued production and exposure to particles over time adversely affects bone formation and resorption, resulting in periprosthetic osteolysis. Current animal models of particle-induced periprosthetic osteolysis have used either a single injection of particles, which is not representative of the clinical scenario, or more advanced animal species. The goal of this study was to develop and validate a murine model of continuous particle infusion in an intramedullary environment. Materials and Methods: UHMWPE: UHMWPE particles were isolated from serum collected from in vitro hip joint simulation tests (Hospital for Special Surgery, New York). The mean diameter of the particles was <1 μm. The Limulus Amoebocyte Lysate assay (BioWhittaker, Waldersville,MD) was performed to ensure that the particles were endotoxin free. Approximately 5 x 10 10 particles were reconstituted in mouse serum (the carrier) and loaded into each pump (0.25μl/hour delivery rate, Durect, Cupertino, CA) for infusion. Animals: Institutional guidelines for the care and use of laboratory animals were strictly followed. Eight-week-old, wild type C57/b16 male mice were used in this study. Animals were divided into two groups randomly. One group of animals (N=13) had a right femoral rod and infusion of carrier solution alone without particles, and a left non-operated limb. The other group of animals (N =10) received bilateral femoral rod implants. In these 10 mice, UHMWPE particles in carrier solution were infused over a 4-week period using an infusion pump and tubing in the right femur only. Surgical Procedure: General anesthesia was induced by 3% isoflurane in 100% Oxygen. Using sterile technique, the intercondylar notch of the distal femur was exposed through a medial parapatellar arthrotomy. A 23-gauge needle was used to manually drill through the intercondylar notch to access the medullary cavity. A 23-gauge rod, 6-mm long, was press fit into the distal femur. When indicated, the rod was connected to polyvinyl tubing and an Alzet pump implanted subcutaneously between the scapulae. After implant insertion, the quadriceps-patellar complex was repositioned and the medial quadriceps arthrotomy and dorsal incision for the pump were repaired with 5.0 Vicryl sutures. Euthanasia was carried out in a CO2 chamber 4 weeks after surgery. Microcomputed tomography analysis: A detailed qualitative and quantitative 3-D evaluation of the femur was performed of the distal 2/5 of each femur using a Scanco Viva40 microCT scanner at 10 micrometer resolution. A fixed threshold was applied to assess mineralized bone on the grey scale images. The bone volume divided by total volume (BV/TV) was used for statistical analysis. Alkaline Phosphatase Staining: The expression of Alkaline Phosphatase (Alk Phos) was detected by a monoclonal antibody (Cat #: AF2910, R&D systems) on decalcified femur embedded in paraffin. The positively stained area was quantified using Image Pro software. The positive staining area divided by tissue section area was used for statistical analysis. Statistical Analysis : Paired t-test was performed to compare the left femur with the right femur for each animal group. Results: For the first group of animals that received carrier infused on one side and had a contralateral non-operated femur, the amount of bone contained in the distal 2/5 of the femur did not differ (Figure 1a). In contrast, infusion of UHMWPE significantly reduced the bone volume when compared to the contralateral side of the same animal in which the rod alone was implanted (Figure 1b). The BV/TV obtained from micro CT scans. The control group: animals had a right femoral rod and infusion of carrier solution alone without particles, and a left non-operated limb. The Experimental group: Animals received bilateral femoral rod implants and UHMWPE particles in carrier solution were infused to the right femur.
منابع مشابه
Preparation of Ultra High Molecular Weight Polyethylene Using Ziegler-Natta Catalyst System: Optimization of Parameters by Response Surface Methodology
متن کامل
In vivo response to cross-linked polyethylene and polycarbonate-urethane particles.
This study was undertaken to examine macrophage response to polycarbonate-urethane, a proposed alternative material to polyethylene in acetabular components of total hip arthroplasty. Polyethylene wear debris from total joint replacements has been linked to osteolysis and implant lifespan. It has been shown in vitro, that polyethylene particles cleaned of endotoxin generate less of an inflammat...
متن کاملGeneration of a large volume of clinically relevant nanometre-sized ultra-high-molecular-weight polyethylene wear particles for cell culture studies
It has recently been shown that the wear of ultra-high-molecular-weight polyethylene in hip and knee prostheses leads to the generation of nanometre-sized particles, in addition to micron-sized particles. The biological activity of nanometre-sized ultra-high-molecular-weight polyethylene wear particles has not, however, previously been studied due to difficulties in generating sufficient volume...
متن کاملIdentification of nanometre-sized ultra-high molecular weight polyethylene wear particles in samples retrieved in vivo.
Nanometre-sized particles of ultra-high molecular weight polyethylene have been identified in the lubricants retrieved from hip simulators. Tissue samples were taken from seven failed Charnley total hip replacements, digested using strong alkali and analysed using high-resolution field emission gun-scanning electron microscopy to determine whether nanometre-sized particles of polyethylene debri...
متن کاملPolyethylene Particles Induce Osteolysis in Calvaria of Wild-type Andimmunodeficient Mice
Introduction: Osteolysis around orthopaedic implants, a consequence of the wear process, is a major problem for the long-term survival of the implants. We and others previously reported quantitative versions of the murine calvarial model of titanium particle induced osteolysis [1,2]. However, the most common particle type that is generated from orthopaedic implants is ultrahigh molecular weight...
متن کاملAnti-oxidation Treatment of Ultra High Molecular Weight Polyethylene Components to Decrease Periprosthetic Osteolysis: Evaluation of Osteolytic and Osteogenic Properties of Wear Debris Particles in a Murine Calvaria Model
Wear debris-induced osteolysis remains the greatest limitation of long-term success for total joint replacements with ultra-high molecular weight polyethylene (UHMWPE) bearings. To address oxidative degradation post-gamma irradiation, manufacturers are investigating the incorporation of antioxidants into PE resins. Similarly, larger molecular weight monomers have been developed to increase cros...
متن کامل