Technetium-99m Ceftizoxime Kit Preparation
نویسندگان
چکیده
The aim of this work was to prepare a kit of Tc-ceftizoxime (Tc-CFT), with stability and biological activity preserved, able to identify a septic focus (E. coli) in the experimental infection model in rats. The preparation of the CFT kit involved the use of lyophilized solutions containing the antibiotic ceftizoxime and the sodium dithionite reducing agent (6.0 mg/mL). After lyophilization, the kit was reconstituted with 1.0 mL of sodium Tcpertechnetate solution (NaTcO4-) with an activity of 370 MBq. The solution was boiled for 10 min and filtered through a cellulose ester filter. The labeling efficiency was on the order of 92%, remaining stable for six hours and the kit remained stable for two months. The biological activity of the Tc-CFT was evaluated by diffusion in agar impregnated with E.coli and S. aureus. Seven Wistar rats, weighing from 200 to 250 g, were used for the development of the septic focus. After 24 hours from the induction of the infectious site (E.coli), the animals were anesthetized and 0.1 mL of Tc-CFT (37 MBq) was injected into the tail veins of the animals. The images were obtained with a gamma camera one, two and six hours after injection and the regions of interest (ROIs) were calculated. The diameters of the inhibition halos for Tc-CFT were 27.16 ± 0.23 and 27.17 ± 0.20 for S.aureus and E.coli, respectively, while those for the unlabeled CFT were 30.4 ± 0.33 and 29.43 ± 0.26, respectively. The results for the biodistribution of Tc-CFT in infected animals furnished a ratio of 1.97 ± 0.31, 2.10 ± 0.42 and 2.01 ± 0.42 for cpm-target/cpm-no target for the one, two and six-hour periods, respectively. The images showed a clear uptake of labeled antibiotic (Tc-CFT) by the infectious site during the experiment. The results attest to the viability of producing a kit with technetium-labeled ceftizoxime for the investigation of infectious processes.
منابع مشابه
Scintigraphic imaging with technetium-99M-labelled ceftizoxime is a reliable technique for the diagnosis of deep sternal wound infection in rats.
PURPOSE To evaluate whether scintigraphy with technetium-99m-labeled ceftizoxime ((99m)Tc-CFT) can differentiate mediastinitis from aseptic inflammation associated with sternotomy. METHODS Twenty female Wistar rats were randomly distributed into four groups: S (control) -partial upper median sternotomy with no treatment; SW (control) - sternotomy and treatment of sternal wounds with bone wax;...
متن کامل99mTc‐aprotinin – optimisation and validation of radiolabelling kits for routine preparation for diagnostic imaging of amyloidosis
Technetium-99m aprotinin was prepared from an optimised radiolabelling kit formulation containing aprotinin, alkaline buffer and stannous chloride (reducing agent) and radiolabelled using (99m) Tc-pertechnetate. The labelling was achieved within 25 min, with radiochemical purities of >98%.
متن کاملTc99m-renal imaging agent--the preparation and comparative clinical evaluation.
Radionuclide Tc99m DTPA (Diethylenetriaminepenta Acetic Acid) renal imaging is being used to assist in the evaluation of overall GFR, the intra-renal transit time, the cortical transit time, response to frusimide injection, diagnosis of ATN and rejection in renal transplant cases. A study was conducted at PINSTECH in order to prepare DTPA kit locally and evaluate the labeling efficiency as well...
متن کاملDirect Technetium radiopharmaceuticals production using a 30MeV Cyclotron
BACKGROUND AND THE PURPOSE OF THE STUDY Technetium-99m is the major radionuclide used in the world and mainly is provided by fission product. However extensive research has been conducted on the use of accelerators for production of (99m)Tc. This investigation reports the production of (99m)Tc radioisotope using cyclotrons and the preparation, quality control and biodistribution studies of four...
متن کاملClinical Evaluation of a New 99mTc-MAA Kit for Lung Scanning
Lung scanning has been recognized as a clinically useful technique for portraying macroscopic pulmonary perfusion defects since it was first reported by Wagner in 1964 (1 ). A number of radiopharmaceuticals have been proposed to assess pulmonary perfusion. Although 1 3 1 I imposes many limitations as a radiotagging agent, the use of iodinated macroaggregated albumin (I-MAA) has received wide ac...
متن کامل