Clinical determination of methemalbumin.
نویسندگان
چکیده
We developed an assay for methemalbumin in biological fluids by using diethylaminoethyl-Sephadex ion-exchange chromatography to separate this protein from interfering components, including hemopexin, transferrin, hemoglobin, and haptoglobin/hemoglobin complex. Initial screening of the samples requires measurement of A280/A405 ratios of the peak tubes of the isolated albumin fraction. Values exceeding 30 indicate that methemalbumin is absent, and no further work is required. Values of less than 30 suggest that methemalbumin is present in the original sample, whereupon the presence and amount of methemalbumin can be ascertained by coloremetric assay for iron with use of ferrozine. Results may be expressed either in terms of micrograms of methemalbumin iron per gram of albumin or in milligrams of methemalbumin per liter. The reproducibility of the method is of the order of +/- 7% (SD). Normal persons have essentially no methemalbumin iron in their serum. Three individuals with hemorrhagic pancreatitis showed values of 65, 98, and 198 mug of methemalbumin Fe per gram of albumin.
منابع مشابه
Methemalbumin interference in various biochemical assays of plasma.
During intravascular hemolysis and digestion of extravasated blood, heme from hemoglobin is oxidized to hematin, hich combines with plasma proteins to form methemalbu(1-4). One case of strong methemalbuminemia (140 oI/L) associated with intravascular hemolysis has been bserved in a patient after placing of an intracardiac valve. e plasma of this patient was so brown that we became terested in t...
متن کاملN-of-1 Clinical Trials: Removing the Hay to Find the Needle.
Significant intravascular hemolysis can complicate dialysis (e.g., because of a kink in a dialysis line) and may result in the formation of methemalbumin (1 ). This gives serum a brown appearance, quite distinct from the typical reddish color associated with extravascular hemolysis. In this case, spectrophotometry performed before and after the addition of a reducing agent (sodium dithionite) (...
متن کاملMethods for measuring plasma hemoglobin in micromolar concentration compared.
Of eight methods examined for measuring plasma hemoglobin in micromolar concentration, all exhibited acceptable linearity, reproducibility, and concurrence except when specimens were icteric or lipemic or contained methemoglobin or methemalbumin. Measurement of absorbance at 578 nm with an Allen correction permits precise assay of plasma oxyhemoglobin concentration as low as 0.01 g/L (1 mg/dL, ...
متن کاملRecent trends in designer drug abuse.
Methemoglobin, myoglobin, and methemalbumin can cause abnormal dark color in patient samples. “Lipemia” was measured at 660and 700-nm wavelengths (1 ); therefore any compounds that absorb light in this range will result in an increased lipemic index. In this patient, methemoglobin was always 7.5% (cooximetry), myoglobin was not detected (gel filtration chromatography and mass spectrometry), but...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 21 10 شماره
صفحات -
تاریخ انتشار 1975