Goniometric measurements of thick tissue using Monte Carlo simulations to obtain the single scattering anisotropy coefficient

نویسندگان

  • Gunnsteinn Hall
  • Steven L. Jacques
  • Kevin W. Eliceiri
  • Paul J. Campagnola
چکیده

The scattering anisotropy, g, of tissue can be a powerful metric of tissue structure, and is most directly measured via goniometry and fitting to the Henyey-Greenstein phase function. We present a method based on an independent attenuation measurement of the scattering coefficient along with Monte Carlo simulations to account for multiple scattering, allowing the accurate determination of measurement of g for tissues of thickness within the quasi-ballistic regime. Simulations incorporating the experimental geometry and bulk optical properties show that significant errors occur in extraction of g values, even for tissues of thickness less than one scattering length without modeling corrections. Experimental validation is provided by determination of g in mouse muscle tissues and it is shown that the obtained values are independent of thickness. In addition we present a simple deconvolution-based method and show that it provides excellent estimates for high anisotropy values (above 0.95) when coupled with an independent attenuation measurement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of dosimetry parameters of two commercially available Iodine brachytherapy seeds using Monte Carlo calculations

Background: Iodine brachytherapy sources with low photon energies have been widely used in treating cancerous tumors. Dosimetric parameters of brachytherapy sources should be determined according to AAPM TG-43U1 recommendations before clinical use. Monte Carlo codes are reliable tools in calculation of these parameters for brachytherapy sources. Materials and Methods: Dosimetric param...

متن کامل

Determination of the scattering coefficient and the anisotropy factor from laser Doppler spectra of liquids including blood.

Laser Doppler measurements were performed on scattering liquids flowing through a highly scattering static medium to determine the scattering coefficient and the anisotropy factor of the liquids. Monte Carlo simulations of light propagation in the static and moving media were used to calculate the Doppler spectra for suspensions of polystyrene spheres in water, and these spectra were in excelle...

متن کامل

A Comparison of the Dosimetric Parameters of Cs-137 Brachytherapy Source in Different Tissues with Water Using Monte Carlo Simulation

Introduction After the publication of Task Group number 43 dose calculation formalism by the American Association of Physicists in Medicine (AAPM), this method has been known as the most common dose calculation method in brachytherapy treatment planning. In this formalism, the water phantom is introduced as the reference dosimetry phantom, while the attenuation coefficient of the sources in the...

متن کامل

Determination of optical properties of human blood in the spectral range 250 to 1100 nm using Monte Carlo simulations with hematocrit-dependent effective scattering phase functions.

The absorption coefficient mu(a), scattering coefficient mu(s), and anisotropy factor g of diluted and undiluted human blood (hematocrit 0.84 and 42.1%) are determined under flow conditions in the wavelength range 250 to 1100 nm, covering the absorption bands of hemoglobin. These values are obtained by high precision integrating sphere measurements in combination with an optimized inverse Monte...

متن کامل

Study of the Compton scattering effect of soft tissue in PET imaging by Monte Carlo method

Introduction:In PET imaging, one or both of two annihilation photons may change the direction before reaching the detector due to Compton scattering interaction in body. .Methods:This article, a Monte Carlo simulation study, examined the effect of soft tissue on this error.In this work, the PET BiographTM 6 scanner, a simple geometry of soft tissue -including a sphere of soft tissue in center ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2012