Detection of early visual field loss in glaucoma using frequency-doubling perimetry and short-wavelength automated perimetry.

نویسندگان

  • John A Landers
  • Ivan Goldberg
  • Stuart L Graham
چکیده

OBJECTIVE To investigate whether frequency-doubling perimetry (FDP) predicts future visual field loss with achromatic automated perimetry (AAP), just as it may be predicted with short-wavelength automated perimetry (SWAP). METHODS We recruited 62 patients selectively from an urban glaucoma practice. At the commencement of the study, each patient had ocular hypertension with normal visual fields on AAP. Baseline SWAP and FDP were performed to determine whether underlying earlier visual field loss was present. Patients were then followed up prospectively for 3 years with annual AAP, SWAP, and FDP. Main Outcome Measure The development of visual field loss on AAP. RESULTS Nine subjects had abnormal SWAP findings and 10 had abnormal FDP findings. At the conclusion of the study, field loss on AAP developed in 5, all of whom had preexisting abnormal SWAP and FDP results. No AAP visual field loss developed in patients with a normal SWAP or FDP. The rate of development of visual field loss on AAP was therefore significantly greater for those with abnormal SWAP (chi21 = 40.83; P<.001) and abnormal FDP findings (chi21 = 32.76; P<.001) than for those with normal SWAP and FDP findings. CONCLUSION In the same way that SWAP may predict AAP visual field loss, FDP may also detect field loss earlier than AAP.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of visual evoked potentials, automated perimetry and frequency-doubling perimetry in early detection of glaucomatous visual field loss.

The present study compares frequency-doubling perimetry (FDP), automated perimetry (AP) and visual evoked potentials (VEP) for their ability to diagnose early glaucoma. In present study 224 patients of Clinic for Eye Diseases, Clinical Hospital "Sestre Milosrdnice" that had diagnosis of open angle glaucoma and glaucomatous visual field loss proven by automated static perimetry on only one eye w...

متن کامل

Visual function-specific perimetry for indirect comparison of different ganglion cell populations in glaucoma.

PURPOSE To compare short-wavelength automated perimetry, frequency-doubling technology perimetry, and motion-automated perimetry, each of which assesses different aspects of visual function, in eyes with glaucomatous optic neuropathy and ocular hypertension. METHODS One hundred thirty-six eyes from 136 subjects were evaluated with all three tests as well as with standard automated perimetry. ...

متن کامل

Comparison of standard automated perimetry, frequency-doubling technology perimetry, and short-wavelength automated perimetry for detection of glaucoma.

PURPOSE To compare the performance of standard automated perimetry (SAP), frequency-doubling technology (FDT) perimetry, and short-wavelength automated perimetry (SWAP) in detecting glaucoma. METHODS One hundred thirty-two eyes of 95 glaucoma patients and 37 normal subjects had retinal nerve fiber layer (RNFL) imaging and visual field testing by SAP, Matrix FDT perimetry, and Swedish interact...

متن کامل

Frequency Doubling Perimetry

DOS Times Vol. 11, No. 6 December, 2005 The goal of perimetry is to establish an accurate estimate of visual field sensitivity. Perimetry is performed to detect early visual field defects, determine specific patterns of visual field loss for differential diagnosis and monitor for evidence of progression of field loss. Conventionally Standard Achromatic Perimetry (SAP) has been used to achieve t...

متن کامل

Diagnostic tools for glaucoma detection and management.

Early diagnosis of glaucoma is critical to prevent permanent structural damage and irreversible vision loss. Detection of glaucoma typically relies on examination of structural damage to the optic nerve combined with measurements of visual function. To aid the clinician in evaluation of visual function and structure, computer-based devices such as confocal scanning laser ophthalmoscopy, scannin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of ophthalmology

دوره 121 12  شماره 

صفحات  -

تاریخ انتشار 2003