Application of European Commission reference dose levels in CT examinations in Crete, Greece.
نویسندگان
چکیده
The purpose of this study was to apply European Commission reference dose levels (EC RDLs) to routine CT examinations. The dosimetric quantities proposed in the European Guidelines (EG) for CT are weighted computed tomography dose index (CTDI(w)) for a single slice and dose-length product (DLP) for a complete examination. Patient-related data as well as technical parameters for brain, chest, abdomen and pelvis examinations were collected for four CT scanners in the Euromedica Medical Center. Computed tomography dose index (CTDI) measurements were performed on each scanner and CTDI(w), DLP and effective dose E were estimated for each type of examination for a random sample of 10 typical patients. Mean values of CTDI(w) had a range of 27.0-52.0 mGy for brain and 13.9-26.9 mGy for chest, abdomen and pelvis examinations. Mean values of DLP had a range of 430-758 mGy cm for brain, 348-807 mGy cm for chest, 278-582 mGy cm for abdomen and 306-592 mGy cm for pelvis examinations. Mean values of E were 1.4 mSv for brain, 10.9 mSv for chest, 7.1 mSv for abdomen and 9.3 mSv for pelvis examinations. Results confirm that the Euromedica Medical Center meets EC RDLs for brain, abdomen and pelvis examinations, in terms of radiation dose and examination technique. As far as chest examination is concerned, although CTDI(w) of each scanner is within proposed values, the DLP is consistently exceeded, probably because of the large irradiation volume length L. It is anticipated that a reduction of L, or product mAs, or their combination, will reduce DLP without affecting image quality.
منابع مشابه
Assessment of Patient Dose from CT Examinations in Khorasan, Iran
Introduction Computed Tomography scans are a very important tool for diagnosis and assessment of response to treatment in the practice of medicine. Ionizing radiation in medical imaging is undoubtedly one of the most powerful diagnostic tools in medicine. Yet, as with all medical interventions, there are potential risks in addition to the clear potential benefits. Materials and Methods Two refe...
متن کاملAssessment and evaluation of patient doses in adult common CT examinations towards establishing national diagnostic reference levels
Background: Patient radiation doses from computed tomography (CT) are increasing due to the number of CT examinations performed every day. The aim of this study was assess and evaluate patient radiation doses for adult’s common CT examinations to derive local diagnostic guidance levels for common CT examinations. Materials and Methods: Volume and weighted computed tomography dose index (C...
متن کاملDiagnostic Reference Levels for Computed Tomography Examinations in Iran: A Nationwide Radiation Dose Survey
Introduction: International Commission on Radiological Protection introduced three basic principles of radiation protection, namely justification, optimization, and dose limit. Medical exposure has no dose limits, and generally, diagnostic reference levels are used as a tool for optimization of patient protection. Material and Methods: Dosimetry was performed on 20 CT scanners located in 14 cit...
متن کاملConventional and spiral CT dose indices in Yazd general hospitals, Iran
ABSTRACT Background: While the benefits of Computed Tomography (CT) are well known in accurate diagnosis, those benefits are not risk free. CT is a device with higher patient dose in comparison with other conventional radiological procedures. Is the reduction of exposures by requiring optimization of CT procedures [a principle concern in radiological protection]? In this study, the radiatio...
متن کاملDiagnostic Reference Level of Computed Tomography Examinations and Need for Dose Optimization in Ondo State, Nigeria
Introduction: The present study was conducted to obtain State diagnostic reference levels (DRLs) of five routine computed tomography (CT) examinations from two CT centers in Ondo State and to identify factors responsible for dose variation and escalation in these CT centers. Material and Methods: Acquisition parameters and CT dose indices wer...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of radiology
دوره 74 885 شماره
صفحات -
تاریخ انتشار 2001