Automated segmentation of psoas major muscle in X-ray CT images by use of a shape model: preliminary study.

نویسندگان

  • Naoki Kamiya
  • Xiangrong Zhou
  • Huayue Chen
  • Chisako Muramatsu
  • Takeshi Hara
  • Ryujiro Yokoyama
  • Masayuki Kanematsu
  • Hiroaki Hoshi
  • Hiroshi Fujita
چکیده

Our motivation was to provide an automatic tool for radiologists and orthopedic surgeons for improving the quality of life of an aging population. We propose a method for generating a shape model and a fully automated segmenting scheme for the psoas major muscle in X-ray CT images by using the shape model. Our approach consists of two steps: (1) The generation of a shape model and its application to muscle segmentation. The shape model describes the muscle's outer shape and has two parameters, an outer shape parameter and a fitting parameter. The former was determined by approximating of the outer shape of the muscle region in training cases. The latter was determined for each test case in the recognition process. (2) Finally, the psoas major muscle was segmented by use of the shape model. To evaluate the performance of the method, we applied it to CT images for constructing the shape models by using 20 cases as training samples; 80 cases were used for testing. The accuracy of this method was measured by comparison of the extracted muscle regions with regions that were identified manually by an expert radiologist. The experimental results of the segmentation of the psoas major muscle gave a mean Jaccard similarity coefficient of 72.3%. The mean true segmentation coefficient was 76.2%. The proposed method can be used for the analysis of cross-sectional area and muscular thickness in a transverse section, offering radiologists an alternative to manual measurement for saving their time and improving the reproducibility of segmentation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Extra osseous uptake of 99mTc-MDP in psoas muscle on bone scintigraphy: Importance of SPECT/CT imaging

Incidental extra-osseous uptake of 99mTc-MDP on bone scintigraphy has been frequently reported in the literature; however, calcification of the psoas muscle is a rare condition, which has been reported on magnetic resonance (MR) and computed tomography (CT) imagings. Here we report a 67-year-old woman with acute paraplegia and low back pain who was referred for a 99mTc-MDP...

متن کامل

Multi atlas-based muscle segmentation in abdominal CT images with varying field of view

The development of automatic techniques for the analysis of abdominal CT images is a topic of large interest. By using automatic techniques, objective diagnostic support can be provided to physicians and organ segmentation can eliminate time-consuming manual procedures such as delineation. Automatic kidney segmentation has been achieved for healthy cases but is unsuccessful in cases with diseas...

متن کامل

Solitary Psoas Muscle Metastasis of Gastroesphageal Junction Adenocarcinoma

Metastasis of gastroesphageal junction (GEJ) adenocarcinoma in skeletal muscle is rare and primary sites for skeletal muscle metastases are usually lung, renal and colorectal cancer. We have encountered with the first case report of solitary psoas muscle metastasis of GEJ adenocarcinoma. Here we describe a 65 years old man was diagnosed with GEJ adenocarcinoma in tertiary hospital, Tehran, Iran...

متن کامل

Model-Based Approach to Recognize the Rectus Abdominis Muscle in CT Images

Our purpose in this study is to develop a scheme to segment the rectus abdominis muscle region in X-ray CT images. We propose a new muscle recognition method based on the shape model. In this method, three steps are included in the segmentation process. The first is to generate a shape model for representing the rectus abdominis muscle. The second is to recognize anatomical feature points corre...

متن کامل

Automated classification of pulmonary nodules through a retrospective analysis of conventional CT and two-phase PET images in patients undergoing biopsy

Objective(s): Positron emission tomography/computed tomography (PET/CT) examination is commonly used for the evaluation of pulmonary nodules since it provides both anatomical and functional information. However, given the dependence of this evaluation on physician’s subjective judgment, the results could be variable. The purpose of this study was to develop an automated scheme for the classific...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiological physics and technology

دوره 5 1  شماره 

صفحات  -

تاریخ انتشار 2012