Dose profiles in ECAL crystals for various irradiation conditions
نویسنده
چکیده
Simulated dose profiles in various irradiation and beam test conditions are compared to the expected dose profiles in the ECAL crystals at LHC. Simple front or side irradiations with photons give too steep or too flat dose profiles, respectively. Thus, if dose maxima are fitted to agree, front irradiation underestimate the average dose whereas side irradiations tend to overestimate. Different profiles are difficult to compare reliably, but it seems likely that in both cases the discrepancy is about a factor of 2–3 but in different directions. For most purposes this is likely to be good enough, but should be taken into account in the interpretation of the test results. It is shown that using a customized lead mask between the source and the crystal can significantly improve the agreement between 60Co side irradiations and the LHC predictions. A 400 MeV/c pion beam incident on a crystal matrix can also reproduce rather well the profiles expected in the barrel ECAL.
منابع مشابه
Evaluation of the Effects of Inhomogeneities on Dose Profiles Using Polymer Gel Dosimeter and Monte Carlo Simulation in Gamma Knife
Introduction Polymer gel dosimeters offer a practical solution to 3D dose verification for conventional radiotherapy as well as intensity-modulated and stereotactic radiotherapy. In this study, EGSnrc calculated and PAGAT polymer gel dosimeter measured dose profiles from single shot irradiation with 18 mm collimator of Gamma Knife in homogeneous and inhomogeneous phantoms were compared with eac...
متن کاملStudies On The Protein Profiles Of Gamma Ray Induced Blood Stage Of Plasmodium berghei For Developing Candidate Of Malaria Vaccine
Ionizing radiation is a known physical agent that had been widely used to attenuate the invasive blood stage of malaria parasite, merozoite, in vaccine materials development. In this study, we determined the protein profiles of blood stage Plasmodium berghei of ANKA strain post gamma irradiation. Parasitized bloods obtained from various percentage of parasite density, days post infection, doses...
متن کاملدزیمتری in-vivo در پرتودرمانی خارجی تومورهای مغزی تحت درمان با فوتون MV15 با استفاده از فیلم گاف کرومیک EBT3
Background and purpose: In-vivo dosimetry is used to ensure accurate delivery of dose to tumors during radiotherapy. This study aimed at measuring the entrance doses without the build-up cap for patients undergoing 15MV radiotherapy and determining the percentage errors between doses measured by films and those calculated with a treatment planning system (TPS). Materials and methods: The stu...
متن کاملCrystals for high-energy calorimetry in extreme environments
Crystals are used as a homogeneous calorimetric medium in many high-energy physics experiments. For some experiments, performance has to be ensured in very difficult operating conditions, like a high radiation environment, very large particle fluxes, high collision rates, placing constraints on response and readout time. An overview is presented of recent achievements in the field, with particu...
متن کاملاثر پرتو گاما بر میزان رشد و تعیین دز مناسب به منظور افزایش تنوع ژنتیکی در ارقام بومی برنج (Oryza Sativa L.)
Mutation breeding as an alternative to conventional breeding, is commonly used to improve current varieties and to generate new varieties. Genetic variation in rice is very low, because of its self-pollination. This study, carried out to determine the GR50 dosage for an irradiation mutagenesis study on the rice and to determine the effects of gamma irradiation on germination and growth rate of ...
متن کامل