Fracture Rate and Serious Complications of Vena Cava Filters
نویسندگان
چکیده
Purpose: To retrospectively evaluate the prevalence of fracture and fragment embolization of inferior vena cava (IVC) filters. Methods: Electronic medical records and imaging studies of all Kaiser Permanente patients who received IVC filters from August 2000 until August 2010 were retrospectively reviewed for filter complications. Results: 283 patients received an IVC filter during the study period. 143 patients were deceased, while 140 are living. Among deceased patients, the average age at the time of death was 69.8 ± 15.3 [range: 24.7 99.2] years; 55.9% were men; the mean implantation-to-image time was 13.6 ± 20.6 [range: 0 92.4] months, and there were no reported major complications attributable to filter migration or fracture at a mean of 16.8 ± 24.8 [range: 0 119.6] months following implantation. One of 14 (7.1%) G2 filters perforated the aorta, which already had a stent graft in place. Among those patients still living, the average age was 67.3 ± 15.2 [range: 15.2 97.3] years, 47.1% were men, the mean implantation-to-image time was 33.3 ± 36.5 [range: 0.1-141.7] months, and there were no reported major complications at a mean of 35.3 ± 36.5 [range: 0 141.7] months following implantation. Three of 60 (5.0%) Trapease filters were found to have at least 1 strut fracture. There were no cases of filter migration or fragment embolization. The overall fracture rate of all filters with an implantation-to-image-time greater than two years (mean implantation-to-image time 4.7 ± 2.7 [range: 2.0 11.8] years) was 3 of 67 (4.5%). Bard G2 and G2X filters had a 0% fracture and embolization rate at a mean of 19.0 ± 16.6 [range: 0.07 49.5] months after implantation. Conclusions: IVC filters, regardless of type, have a low prevalence of fracture and we found no cases of fragment embolization.
منابع مشابه
Delayed Lumbar Artery Laceration and Symptomatic Retroperitoneal Hemorrhage Following IVC Filter Placement
Inferior vena cava filters are placed in selected patients to protect against potentially fatal pulmonary embolism. Generally, filter placement is regarded as a safe procedure although rare complications may arise. Recurrent thromboembolic events are the most common complications associated with inferior vena cava filters; however, there are multiple reports of filter fracture, migration, embol...
متن کاملRecurrent Fracture of a Recovery Inferior Vena Cava Filter with Pulmonary Migration
Inferior vena cava (IVC) filters are indicated in patients with venous thromboembolic disease in whom standard anticoagulation therapy is contraindicated or ineffective. A 32-year-old female presented to our hospital with chest pain 5 years after IVC filter placement. Imaging revealed sequential fracturing and embolization of two of the IVC filter arms to the pulmonary arteries. IVC filter frac...
متن کاملUsing inferior vena cava filters to prevent pulmonary embolism.
OBJECTIVE To review the evidence for using inferior vena cava (IVC) filters to prevent pulmonary embolism (PE) in high-risk patients. QUALITY OF EVIDENCE Ovid MEDLINE was searched from 1966 to 2006 for all English-language papers on IVC filters. Evidence was graded according to the 3-level classification system. Most evidence found was level II. MAIN MESSAGE Inferior vena cava filters are u...
متن کاملSystematic review of the use of retrievable inferior vena cava filters.
PURPOSE To review the available literature on retrievable inferior vena cava (IVC) filters to examine the effectiveness and risks of these devices. MATERIALS AND METHODS Investigators searched MEDLINE for clinical trials evaluating retrievable filters and reviewed the complications reported to the Manufacturer and User Facility Device Experience (MAUDE) database of the U.S. Food and Drug Admi...
متن کاملPenetration of an inferior vena cava filter into the aorta.
Transvenous placement of inferior vena cava (IVC) filters is commonly performed in selected patients with deep venous thrombosis and pulmonary embolism. However, filter placement is sometimes associated with serious complications. A common complication is asymptomatic perforation of the IVC and penetration of adjacent organs by the filter. Here, we report a case of an 83-year-old man whose prop...