The Measurement of Intravenous Temperatures
نویسنده
چکیده
The temperatures of various parts of the body, as determined with the ordinary clinical thermometer are, in general, different, and the differences are not always consistent. We cannot assume, therefore , that such measurements give a true index of the mean internal temperature of the body, which may perhaps best be identified with the temperature of the blood flowing in large blood vessels. Moreover the instrument itself is not free from objection. Its heat capacity is sufficiently great to lower appreciably for some time the temperature of tissue with which it comes in contact, and its response is too slow to follow fluctuations found with more sensitive apparatus. Although measurements made with a clinical thermometer are doubtless quite satisfactory for most purposes, it is possible that, for certain kinds of experimental work, fairly accurate determinations of blood temperatures may prove interesting. Apparatus which has been devised for this purpose by the author is described below. The temperatures are measured by a thermoelectric method, in which one makes use of the fact that the discontinuity of electric potential at a junction of two dissimilar metals depends only on the nature of the metals and the temperature of the junction. A closed circuit of two metals contains, of course, two opposed junctions. If the second of these junctions is kept at a known constant temperature, the resultant thermoelectric" force in the circuit is the difference between the potential discontinuities at the two junctions, and this is a function of the temperature of the first junction only. This thermoelectromotive force may be used ill either of two ways to measure temperature. It may be measured directly by means of 385
منابع مشابه
بررسی صحت و دقت دمای تمپانیک در بازتاب دمای مرکزی بدن
Background & Aim: Monitoring of patients' temperature is an important nursing clinical procedure. Body temperature is usually taken at different sites including pulmonary artery, rectal, oral, and axillary areas. Currently, infrared tympanic temperature measurement method is increasingly used as a convenient, noninvasive and rapid method. However, accuracy and precision of this method has bee...
متن کاملAccidental intravenous bolus infusion of potassium chloride in a young man with hypokalemic periodic paralysis
Hypokalemic periodic paralysis is anautosomal dominantdisease characterized by muscle weakness or paralysis with a matching fall in blood potassium levels. Paralysis attacks often occur in adolescence and are induced by strenuous exercise followed by rest, high carbohydrateor high sodiummeal content, sudden changes in temperature, and even excitement, noise, flashing lights and cold temperature...
متن کاملExperimental measurement of dynamic viscosity of CeO2-EG at different concentrations and temperatures and proposing a new correlation
Nanofluid is prepared through the nanoscale particles suspended in a fluid base and Nanotechnology is a new attempt to investigate the thermal sciences. As a result of huge investment in developed countries on nanotechnology, research on thermal properties of nano-fluids is of particular interest.Due to the usage of nanotechnology to reduce energy waste, in this project CeO2 with EG is used to ...
متن کاملExperimental Measurement of Dynamic Viscosity of CeO2-EG at Different Concentrations and Temperatures and Proposing a New Correlation
Nanofluid is made through the nanoscale particles suspended in a fluid base and Nanotechnology is a new attempt in thermal science investigations. As a result of huge investment in developed countries on nanotechnology, research on thermal properties of nano-fluids is of particular interest. Due to the usage of nanotechnology to reduce energy consumptions, in this project CeO2 with EG is used t...
متن کاملPerformance of Sife - Eldeen dosimeter over broad absorbed dose and dose rate ranges of γ – radiation and at different temperatures
Background: Results are presented on some dosimetric characteristics of Sife – Eldeen dosimeter based on the radiation induced conductivity (RIC) of 3.5 M aqueous urea solutions. The studied characteristics were the response (RIC) of Sife – Eldeen dosimeter in broad ranges of absorbed dose, dose rates and at different irradiation temperature. Materials and Methods: Kent EIL5007 conductivity met...
متن کاملMeasurement of Volumetric and Viscometric Properties of Binary Mixtures of Methyl Tert-butyl Ether (MTBE) + 1-Alcohol from 293.15 to 308.15 K and at Atmospheric Pressure
Densities and viscosities of binary mixtures of methyl tert-butyl ether (MTBE) with 1-alkanols include 1-butanol, or +1-pentanol, or +1-hexanol, or +1-heptanol were measured as a function of composition from 293.15 to 308.15 K at atmospheric pressure. The temperatures studied were 293.15, 298.15, 303.15 and 308.15 K. The experimental results have been used to calculate the viscosity de...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of Experimental Medicine
دوره 35 شماره
صفحات -
تاریخ انتشار 2003