Over the last few decades many techniques have been developed for determination of Sr/Y in the environment. Čerenkov counting technique (developed in the 1960s) is widely used, but can be further developed by the application of emerging technologies. For example, it is believed that the application of the triple-to-double coincidence ratio (TDCR) liquid scintillation counting method can be used to simplify the measurement of Sr/Y in aqueous solutions. The objective of this study is to discuss the ongoing research to optimize the conditions for determination of Sr/Y activities by the TDCR Čerenkov counting technique.
منابع مشابه
Monte Carlo Dose Calculation of 90 Sr/ 90 Y Source in Water Phantom
Introduction: 90 Sr/ 90 Y source has been used for the intravascular brachytherapy to prevent coronary restenosis in the patients who have undergone angioplasty. The aim of this research is to determine the dose distribution of 90 Sr/ 90 Y source in a water phantom. Materials and Methods: In the present work, MCNP code has been applied to calculate the dose distri...
متن کاملApplication of TDCR-Geant4 modeling to activity standardization
The LNE-LNHB, in charge of the French standards for radionuclide metrology, develops primary measurement methods intended for the calibration of secondary measuring instruments, such as used in hospitals, to determine the activity of radiopharmaceuticals injected into patients. The triple-to-double coincidence ratio (TDCR) method, based on liquid scintillation counting, is widely implemented fo...
متن کاملMeasurements of Strontium-90 in portuguese milk samples using liquid scintillation counting technique
The objective of this study is the implementation of a method combining extraction chromatography and liquid scintillation counting (LSC) technique to the determination of 90Sr in milk samples. The strontium separation is performed using the commercially available Sr-resin (Eichrom) and the beta counting is carried out using a liquid scintillation detector system (Tri-Carb 3170 TR/SL, Packard)....
متن کاملComparison of the Effects of Three Different Counting Methods on Cardiopulmonary Resuscitation Quality and Rescuer Fatigue
Background: Chest compression with adequate depth and number is one of the main indicators of high-quality cardiopulmonary resuscitation (CPR). Nevertheless, no proper counting technique is suggested to provide sufficient number of massages. Aim: To compare the effects of three techniques of chest compression counting on the quality of CPR and rescuer fatigue. Method: Inthis clinical trial, 30 ...
متن کاملEffectiveness Evaluation of Skin Covers against Intravascular Brachytherapy Sources Using VARSKIN3 Code
BACKGROUND AND OBJECTIVE The most common intravascular brachytherapy sources include (32)P, (188)Re, (106)Rh and (90)Sr/(90)Y. In this research, skin absorbed dose for different covering materials in dealing with these sources were evaluated and the best covering material for skin protection and reduction of absorbed dose by radiation staff was recognized and recommended. METHOD Four material...