Wakefield Calculations for 3 D Collimators ∗

نویسنده

  • Igor Zagorodnov
چکیده

Using a recently developed time domain numerical approach we calculate the short-range geometric wakefields of 3D collimators and compare with analytical models. We find, in the diffractive regime, that the transverse mode kick factor can be approximated from the change in field energy between the beam pipe and the collimator if the collimator is long, or using a “field clipping” estimate if it is short. For collimators of past and present measurements at SLAC, numerical, analytical, and measurement results are compared.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transverse Wakefields from Tapered Collimators: Measurements and Analysis

We report on a series of measurements of the transverse wakefield from tapered collimators. The collimators were designed to principally present a geometric impedance to the beam, and to minimize impedances from resistivity or surface features; in addition, the geometries of the collimators were selected to permit examination of the scaling behavior of the wakefield due to collimator taper angl...

متن کامل

Numerical Calculations of Short-range Wakefields of Collimators

The performance of future linear colliders are limited by the effect of short-range collimator wakefields on the beam. The beam quality is sensitive to the positioning of collimators at the end of the linac. The determination of collimator wakefields has been difficult, largely because of the scarcity of measurement data, and of the limitation of applicability of analytical results to realistic...

متن کامل

TESLA Report 2003-18 NUMERICAL CALCULATION OF SMALL-ANGLE COLLIMATOR WAKEFIELDS FOR SHORT BUNCHES

Collimators are used to eliminate halo particles from the beam. To relax the wakefield effects a gradual transition from a large to a small aperture is used. However, the existing computer codes face severe problems for long tapered transitions. Two main sources of the problems are the grid dispersion and the staircase geometry approximation. Using recently developed time domain numerical appro...

متن کامل

Direct Measurement of Geometric Wakefields from Tapered Rectangular Collimators

We present a direct measurement of the short-range wakefield of a series of tapered collimators. The wakefields were measured by inserting a fixed aperture in the path of the electron beam at the 1.19 GeV point of the SLAC linac. As the vertical position of the collimator is varied, the vertical deflection of the beam is measured on 29 downstream beam position monitors. A series of apertures wi...

متن کامل

Measurement of Resistivity Dominated Collimator Wakefield Kicks at the Slc

Collimation of the multi-MW beams in present linear collider designs is a critical issue. Graphite as a possible collimator material exhibits good mechanical properties but a rather poor electrical conductivity. The resulting resistive wakefields can potentially deteriorate the beam quality. The knowledge of strength and scalings of such wakefields is essential for the design of the collimation...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006