Determination of the optimal inspiratory pressure providing adequate ventilation while minimizing gastric insufflation using real-time ultrasonography in Chinese children: a prospective, randomized, double-blind study
نویسندگان
چکیده
BACKGROUND During facemask ventilation, gastric insufflation is defined as appearance of a comet-tail or an acoustic shadow on ultrasonography. Ultrasonographic measurement of antral cross-section area (CSA) may reflect an insufflated antrum and provide interesting semi-quantitative data in regard to the gastric insufflation. This study aimed to determine the appropriate level of inspiratory pressure sufficient to provide adequate pulmonary ventilation with a lower occurrence of gastric insufflation during facemask pressure-controlled ventilation using real-time ultrasonography in paralyzed children. METHODS Ninety children, ASA I-II, aged from 2 to 4 years, scheduled for general anesthesia were enrolled in this randomized and double-blinded study. Children were randomized into one of the five groups (P8, P10, P12, P14, and P16) defined by the applied inspiratory pressure during facemask ventilation: 8, 10, 12, 14, and 16 cm H2O. Anesthesia induction was conducted with fentanyl and propofol. Rocuronium was administrated as a muscle relaxant. After rocuronium administration, facemask ventilation was performed for 120 s. Gastric insufflation (GI+) was detected by ultrasonography, and the antral CSA before and after facemask ventilation were also measured using ultrasonography. Respiratory variables were monitored. RESULTS Gastric insufflation was detected in 32 children (3/18 in group P8, 5/18 in group P10, 7/18 in group P12, 8/16 in group P14, and 9/14 in group P16). The antral CSA after facemask ventilation statistically increased in subgroups P14 GI+ and P16 GI+ for whom gastric insufflation was detected by ultrasonography, whereas it did not change statistically in other groups. Lung ventilation was inadequate for group P8 or P10. CONCLUSION We concluded that an inspiratory pressure of 12 cm H2O is sufficient to provide adequate ventilation with a lower occurrence of gastric insufflation during induction of general anesthesia in paralyzed Chinese children aged from 2 to 4 years old. TRIAL REGISTRATION ( ChiCTR-IPR-16007960 ). Registered 21 February 2016 Conclusion heading: Ultrasound for determining gastric insufflation.
منابع مشابه
A randomized comparison of volume- and pressure-controlled ventilation in children with the i-gel
BACKGROUND The i-gel provides good airway sealing but gastric insufflation may occur when peak inspiratory pressure (PIP) exceeds the sealing pressure of the i-gel without a gastric tube. Pressure-controlled ventilation (PCV) provides lower PIP compared with volume-controlled ventilation (VCV) and low PIP may reduce the incidence of gastric insufflation in children during positive pressure vent...
متن کامل`Evaluation of the analgesic efficacy of melatonin in patients undergoing cesarean section under spinal anesthesia: A prospective randomized double-blind study
Melatonin has been suggested as a new natural pain killer in inflammatory pain and during surgical procedures. We designed this randomized double-blind controlled study to evaluate the analgesic efficacy and also optimal preemptive dose of melatonin in patients undergoing cesarean section under spinal anesthesia.One hundred twenty patients scheduled for cesarean section under spinal anesthesia ...
متن کامل`Evaluation of the analgesic efficacy of melatonin in patients undergoing cesarean section under spinal anesthesia: A prospective randomized double-blind study
Melatonin has been suggested as a new natural pain killer in inflammatory pain and during surgical procedures. We designed this randomized double-blind controlled study to evaluate the analgesic efficacy and also optimal preemptive dose of melatonin in patients undergoing cesarean section under spinal anesthesia.One hundred twenty patients scheduled for cesarean section under spinal anesthesia ...
متن کاملCricoid pressure applied after placement of the laryngeal mask prevents gastric insufflation but inhibits ventilation.
We studied 50 patients, in a blind, crossover study, to assess if cricoid pressure applied after placement of the laryngeal mask prevented gastric insufflation without affecting ventilation. After induction of anaesthesia and neuromuscular block, a laryngeal mask was inserted and confirmed to be placed correctly. The lungs were ventilated with a maximum inflation pressure of 15 cm H2O. In the f...
متن کاملCadaver study of oesophageal insufflation with supraglottic airway devices during positive pressure ventilation in an obstructed airway.
BACKGROUND Supraglottic airway devices (SADs) play an increasing role in airway management in clinical anaesthesia and emergency medicine. Until now, no data exist concerning the extent of oesophageal insufflation when oropharyngeal leak pressures are exceeded. METHODS Laryngeal masks LMA-Supreme™ and LMA-ProSeal™, laryngeal tubes LTS-D and LTS II, Combitube™, and I-Gel were inserted into unf...
متن کامل