Effect of rotatory instrument speed on its capacity to remove demineralized and sound dentin
نویسندگان
چکیده
OBJECTIVES The aim of this study was to evaluate the capacity of two rotatory instruments (controlled speed electric motor [CSEM] - 300 rpm; conventional slow handpiece [CSHP] - 18,000 rpm) to remove sound and demineralized dentin, by examining prepared cavity walls using the scanning electron microscopy (SEM) and assessing loss of mass. MATERIALS AND METHODS A total of 40 blocks of human occlusal dentin, measuring 5 mm × 5 mm × 4 mm (L × W × H), were divided into two groups according to the substrate type in which the cavity preparation was performed: D - demineralized dentin; and S - sound dentin (control group). The groups were subdivided according to the rotatory instrument used for cavity preparation (n = 10): CSEM (300 rpm); and CSHP (18,000 rpm). In half of the dentin blocks, caries lesion induction was performed for 6 weeks. The preparation of the cavities was performed on a standardizing machine, using a cylindrical tungsten carbide burr. Before and after the preparation, specimens were dehydrated in an incubator at 60°C for 30 min. The initial and final mass (in mg) of each dentin block was measured 3 times using the digital precision balance to obtain the mean weight Following cavity preparation, all specimens were hemisected and SEM was used to blindly assess each half so that the lateral walls of the prepared cavity were measured in μm, accepting the average of two measurements as the total depth of the preparation. Non-parametric Mann-Whitney analysis was performed with a 5% of significance level. RESULTS Regarding the weight difference (mg), no significance was detected between the groups. Regarding depth (μm), a significant difference was found between the groups, so that the CSRM showed lower cavity depth when compared with CSHP, both in sound and demineralized dentin. CONCLUSIONS Controlled speed rotatory instruments were found to be more conservative in removing both sound and demineralized dentin, in terms of preparation and depth.
منابع مشابه
بررسی اثر برداشت کلاژن بر میزان استحکام باند برشی چهار سیستم باند عاجی یک جزئی
Background and Aim: Achieving adhesion between restorative materials and dentin as a wet and dynamic surface is an important topic in restorative and especially in conservative dentistry. Adhesion of new dentin bonding systems depends on the formation of hybrid layer and micromechanical retention. Nevertheless, an ideal adhesive system has not yet been introduced .Recent studies reveal an incre...
متن کاملIn-vitro Thermal Maps to Characterize Human Dental Enamel and Dentin
The crown of a human tooth has an outer layer of highly-mineralized tissue called enamel, beneath which is dentin, a less-mineralized tissue which forms the bulk of the tooth-crown and root. The composition and structure of enamel and dentin are different, resulting in different thermal properties. This gives an opportunity to characterize enamel and dentin from their thermal properties and to ...
متن کاملThermal alteration and morphological changes of sound and demineralized primary dentin after Er:YAG laser ablation.
The purpose of this study was to assess the influence of Er:YAG laser pulse repetition rate on the thermal alterations occurring during laser ablation of sound and demineralized primary dentin. The morphological changes at the lased areas were examined by scanning electronic microscopy (SEM). To this end, 60 fragments of 30 sound primary molars were selected and randomly assigned to two groups ...
متن کاملAnalysis of Microstructural Changes of Sound, Demineralized and Denatured Dentin on Application of Carisolv – An In Vitro Study
Abstract BACKGROUND AND OBJECTIVES: The purpose of this study was to analyze the microstructural changes caused by Carisolv gel on sound, demineralized, and denatured dentin. METHOD: A total of 48 freshly extracted human premolars and molars were collected and divided into 3 main groups, Group I contained 12 teeth with fractured dentinal surface, which were further divided into two subgroups IA...
متن کاملShear Bond Strength of Composite to Primary Enamel Treated with Casein Phosphopeptide Amorphous Calcium Phosphate Using Total-Etch and Self-Etch Bonding Systems
Background and Aim: By application of casein phosphopeptide amorphous calcium phosphate (CPP-ACP) as a remineralizing agent, it may be feasible to only remove the carious dentin and better preserve the tooth structure. This study aimed to assess the shear bond strength of composite to primary enamel treated with CPP-ACP using total-etch and self-etch bonding systems. Materials and Methods: T...
متن کامل