Adaptive Nonlinear Control of Three Phase Shunt Active Power Filter with Uncertainties

نویسندگان

  • A. ALLAG
  • M. Y. HAMMOUDI
  • S. M. MIMOUNE
  • M. FELIACHI
چکیده

This paper presents a new control strategy for a three phase shunt active power filter, which consists of applying an adaptive nonlinear control. This technique consists of applying an adaptive nonlinear control to the uncertain nonlinear model of shunt active power filter obtained in (dq) frame by using the power balance between the input and output sides. The designed Adaptive nonlinear controller (ANC) combines the nonlinear feedback linearization technique with linear adaptive control techniques and takes into account the uncertainties in the model parameters .We Apply an adaptive nonlinear control in order to control the line-currents, output DC link voltages and also to reduce the influence of the parameter uncertainty. Simulation results clearly show that the proposed controller has a good performance and robust to the parameter uncertainties compared with other nonlinear strategies controllers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Hybrid Control Method for Stable Operation of Active Power Filters in Three-Phase Four-Wire Networks

The main goal of this study is the use of Lyapunov’s stability theory to a three-phase four-wire shunt active power filter (SAPF), since this method has been applied effectively to other areas of converter. The dynamic model of the SAPF is first established, after that, a combination of fuzzy tracking control and Lyapunov function is suggested in order to impose a desired transient waveform on ...

متن کامل

Indirect Control of Single-Phase Active Power Filters using Harmonic Control Arrays

The ever increase of nonlinear loads in electric distribution networks causes many problems due to the high level of harmonic currents. This paper proposes a new technique for controlling a single phase shunt active power filter based on a selective compensation using the newly developed technique of harmonic control arrays. Simulation results confirm the appropriate selective harmonic compensa...

متن کامل

Adaptive Neuro-fuzzy Inference system based control of three-phase hybrid power filter for harmonic mitigation

This paper presents a three-phase hybrid power filter based on artificial intelligence control approach. It consists of C-type passive filter in parallel with a shunt active filter that is controlled by an adaptive Neuro-Fuzzy inference system (ANFIS) controller. The active filter is based on a three-phase voltage inverter with six control switches. The AC side of the filter is connected in par...

متن کامل

Active Filter Control Method Based on Direct Power Control for Compensating Reactive Powers due to Unbalanced Voltages and Nonlinear Loads

Active filters have proven to be more effective than passive techniques to improve power quality and to solve harmonic and power factor problems due to nonlinear loads. This paper proposes a control scheme based on the instantaneous active and reactive power. The inverter of this active filter is a three-phase, two-level converter. Space vector technique is used as modulators and pattern genera...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016