Nhtsa’s Thor-nt Database

نویسندگان

  • Peter G. Martin
  • Lauren Shook
چکیده

This paper provides a comprehensive overview of the many tests involving the THOR-NT advanced frontal impact dummy that are contained within the NHTSA test database. Since its release in 2005, NHTSA has collected data from over one hundred tests involving the THOR-NT. These include sled tests, vehicle tests, and component tests at different speeds and configurations. This paper serves as a reference for describing the various test series, which include those aimed at assessing biofidelity, evaluating instrumentation, and establishing qualification and injury criteria. This paper also provides analytical examples that demonstrate the utility of the database in studying dummy-related issues. New auxiliary tools, such as data processing software and computer models, are also described. Finally, this paper summarizes some of the lessons learned from this broad test experience, and documents actions that are being taken to enhance dummy performance and acceptance by the international community.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Parent, 1 THORACIC BIOFIDELITY ASSESSMENT OF THE THOR MOD KIT ATD

During the upgrade of the 50th percentile male THOR anthropomorphic test device (ATD) from the Alpha level to the NT level, the low-speed Kroell hub impact corridor was selected as the design requirement for blunt thoracic impact response. Although this requirement was reiterated during the development of the THOR Mod Kit, it has been documented that the response of the thorax does not meet the...

متن کامل

Evaluation of Dummy Shoulder Kinematics in Oblique Frontal Collisions

ABSTRACT The present study evaluates shoulder kinematics of the Hybrid III and THOR NT, with the first version of a new shoulder design (SD-1), in 45° far-side, full frontal and 30° near-side collisions. In total eleven dummy tests were conducted in the three collision angles, while film and instrument data were generated and compared with those of PMHS data from Törnvall (2008). For the 45° fa...

متن کامل

Polarizing pathways: balancing endothelial polarity, permeability, and lumen formation.

nt matter & 2013 Elsevier 016/j.yexcr.2013.03.028 thor at: 555 Mission Bay B [email protected] (A.C.

متن کامل

Distributed Object Management in Thor

Thor is a new object-oriented database management system (OODBMS), intended to be used in heterogeneous distributed systems to allow programs written in diierent programming languages to share objects in a convenient manner. Thor objects are persistent in spite of failures, are highly likely to be accessible whenever they are needed, and can be struc-tured to reeect the kinds of information of ...

متن کامل

Evaluation of the Load Limiting Capabilities of Football Neck Collars using Anthropomorphic Test Devices

The objective of this study was to perform a dynamic biomechanical analysis of neck collars in order to determine their effect on head and neck loading. A total of 48 tests were performed comparing the Cowboy Collar, Bullock Collar, and Kerr Collar. A control and each collar were tested at two speeds (5 m/s and 7 m/s), three impact locations (front, top, and side of the helmet), and two shoulde...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007