Clinical and radiological outcomes of arthroscopically assisted cannulated screw fixation for tibial eminence fracture in children and adolescents

نویسندگان

  • Chang Ho Shin
  • Doo Jae Lee
  • In Ho Choi
  • Tae-Joon Cho
  • Won Joon Yoo
چکیده

BACKGROUND The purpose of this study was to determine the efficacy and complications of arthroscopically assisted reduction and fixation with cannulated screws for tibial eminence fracture in skeletally immature patients. METHODS This was a retrospective case series study. Forty-eight patients who were skeletally immature at the time of tibial eminence fracture were treated in a tertiary children's hospital between May 2004 and August 2015. Twenty-one patients were excluded due to non-operative treatment (n = 10), other surgical treatments (n = 9), multiple fracture (n = 1), and follow-up < 1 year (n = 1). Twenty-seven knees of 27 patients were analyzed. Avulsed fragment was reduced arthroscopically. One to three cannulated screws (4.0 mm or 5.0 mm in diameter) were used for fixation. Passive knee motion was started in 3-4 weeks. Clinical outcomes were evaluated by Lysholm score, instability of the knee, and complications. Radiological outcomes including nonunion and malunion of the avulsed fragment and physeal growth disturbance were evaluated. RESULTS Mean age at the time of surgery was 10.1 years (range, 6.2 to 13.8 years). Patients were followed up for a mean of 3.9 years (range, 1.0 to 7.6 years). Fracture types included type III (n = 13), type II (n = 12), and type IV (n = 2) according to Zaricznyj modification of Meyers and McKeever classification. Meniscus was entrapped in five patients. Six patients showed concomitant meniscal tear. Mean Lysholm score at the latest follow-up was 95 (range, 78 to 100). Joint instability was not observed in any patient except one (instability of 5-10 mm). All patients showed full range of knee motion except one (10 degrees of flexion contracture). Screw head impingement against intercondylar notch of the femur was observed in two patients during screw removal procedure. Five knees showed prominent tibial eminence without symptoms. The injured lower limb was longer than the contralateral normal side by a mean of 6.2 mm (range, - 4 to 18 mm). CONCLUSIONS Arthroscopically assisted reduction and fixation with cannulated screws is an effective and safe surgical option for treating tibial eminence fracture with few complications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Outcomes and second-look arthroscopic evaluation after combined arthroscopic treatment of tibial plateau and tibial eminence avulsion fractures: a 5-year minimal follow-up

BACKGROUND Tibial eminence avulsion fracture often co-occurs with tibial plateau fracture, which leads to difficult concomitant management. The value of simultaneous arthroscopy-assisted treatment continues to be debated despite its theoretical advantages. We describe a simple arthroscopic suture fixation technique and hypothesize that simultaneous treatment is beneficial. METHODS Patients wi...

متن کامل

Pediatric tibial eminence fractures: arthroscopic treatment using K-wire.

BACKGROUND Fractures of the tibial intercondylar eminence are observed mostly in children and adolescents, often after minimal trauma. The purpose of this paper is to evaluate the use of K-wire fixation for the arthroscopic treatment of tibial eminence fractures in children. PATIENTS AND METHODS From January 2002 through January 2009 ten patients were treated arthroscopically because of the i...

متن کامل

Arthroscopic 4-point suture fixation of anterior cruciate ligament tibial avulsion fractures.

Tibial eminence avulsion fractures are rare injuries occurring mainly in adolescents and young adults. When necessary, regardless of patient age, anatomic reduction and stable internal fixation are mandatory for fracture healing and accurate restoration of normal knee biomechanics. Various arthroscopically assisted fixation methods with sutures, anchors, wires, or screws have been described but...

متن کامل

Arthroscopic Fixation Of Avulsion Fractures

BACKGROUND: Identification and treatment of type II and type III injuries, combined with the need for accurate reduction of these fractures to assure stability of the knee postoperatively, make arthroscopic examination critical in the successful treatment of these fractures .Several recent reports describe techniques and experiences with arthroscopic fixation of type III fractures using sutures...

متن کامل

Physeal-sparing tibial eminence fracture fixation with a headless compression screw.

Displaced tibial intercondylar eminence fractures frequently require operative fixation. Surgical techniques for fixation include the use of headed screws or sutures. However, these fractures commonly occur in skeletally immature patients, and current techniques violate the proximal tibial physis to maintain reduction and can result in growth disturbances. The authors present a physeal-sparing ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 19  شماره 

صفحات  -

تاریخ انتشار 2018