Design of an in-vivo multi-spectral confocal microendoscope for clinical trials

نویسندگان

  • Andrew R. Rouse
  • Anthony A. Tanbakuchi
  • Joshua A. Udovich
  • Arthur F. Gmitro
چکیده

We previously reported on the development and testing of a multi-spectral confocal microendoscope. Here we present a new system that will be used during an early stage clinical trial. The new microendoscope is significantly smaller, uses fewer optical elements, and is structurally more robust. The slit-scanning confocal system employs two synchronized single-axes scan mirrors and an externally coupled imaging catheter with automated focus control and dye delivery systems. In grayscale collection mode the confocal microendoscope operates at 30 frames-per-second with 3μm lateral resolution and 25μm axial resolution. The multi-spectral collection mode operates at 0.5 frames-per-second when acquiring 32 spectral channels with an average minimum resolvable wavelength difference of 12nm. The system will be used, in grayscale mode, to image ovaries during a small scale clinical trial on women undergoing oophorectomy. Recent grayscale and multi-spectral imaging results from ex-vivo human tissues are presented.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and Performance of a Multi-Point Scan Confocal Microendoscope.

Confocal fluorescence microendoscopy provides high-resolution cellular-level imaging via a minimally invasive procedure, but requires fast scanning to achieve real-time imaging in vivo. Ideal confocal imaging performance is obtained with a point scanning system, but the scan rates required for in vivo biomedical imaging can be difficult to achieve. By scanning a line of illumination in one dire...

متن کامل

Multispectral confocal microendoscope for in vivo and in situ imaging.

We describe the design and operation of a multispectral confocal microendoscope. This fiber-based fluorescence imaging system consists of a slit-scan confocal microscope coupled to an imaging catheter that is designed to be minimally invasive and allow for cellular level imaging in vivo. The system can operate in two imaging modes. The grayscale mode of operation provides high resolution real-t...

متن کامل

Multispectral imaging with a confocal microendoscope.

The concept of a multispectral confocal microscope for in vivo imaging is introduced. To demonstrate the concept we modified a slit-scan fluorescence confocal microendoscope incorporating a fiber-optic catheter for in vivo imaging to record multispectral images. The system was designed to examine cellular structures during optical biopsy and to exploit the diagnostic information contained withi...

متن کامل

In-vivo multi-spectral confocal microscopy

A multi-spectral confocal microendoscope (MCME) for in-vivo imaging has been developed. The MCME employs a flexible fiber-optic catheter coupled to a slit-scan confocal microscope with an imaging spectrometer. The catheter consists of a fiber-optic imaging bundle linked to a miniature objective and focus assembly. The focus mechanism allows for imaging to a maximum tissue depth of 200 microns. ...

متن کامل

Design and demonstration of a miniature catheter for a confocal microendoscope.

The fluorescence confocal microendoscope provides high-resolution, in vivo imaging of cellular pathology during optical biopsy. The confocal microendoscope employs a flexible fiber-optic catheter coupled to a custom-built slit-scan confocal microscope. The catheter consists of a fiber-optic imaging bundle linked to a miniature objective and focus assembly. The 3-mm-diameter catheter may be used...

متن کامل