Determination of bisphenol A in beer by immunoaffinity column tandem high-performance liquid chromatography
نویسندگان
چکیده
KEYWORD: bisphenol A; immune-affinity column; high-performance liquid chromatography ABSTRACT: A rapid and sensitive method using immuno-affinity columns (IACs) as sample purification procedure and high-performance liquid chromatography (HPLC) tandem fluorescence detector (FLD) for detection has been developed for the determination of bisphenol A (BPA) in beer. The limit of detection (LOD) is 0.28 ng/ml (S/N=3) and the limit of quantity (LOQ) is 0.95 ng/ml (S/N=10). For standard adding and recovery experiments toward beer sample with addition of fourlevel bisphenol A, the average recovery ratio range from 74.56% to 97.60%, and the relative standard deviations (RSD) range 1.04% to 9.77%. In conclusion, this method is an appropriate way for detection of BPA. For the detection of canned beer samples of various brands, the detection rate is as high as 100%.
منابع مشابه
Determination of Aflatoxins B1 and B2 in Powdered Milk Using Modified Liquid Chromatography Method
Background & Aims: In this study, using a liquid-liquid microextraction method for pre-concentration trace amounts of aflatoxins, the amount of Aflatoxins B1 and B2 in powdered milk was determined. Determination of aflatoxins was done by using high-performance liquid chromatography coupled with fluorescent detector. Method: Samples were extracted by immunoaffinity column (IAC) clean-up, and the...
متن کاملRelative Determination Approach to the Metabolites of Protoberberine Alkaloids in Rat Urine by Liquid Chromatography Tandem Mass Spectrometry for the Comparative Studies on Rhizome coptidis and Zuojinwan Preparation
The lack of authentic standards has limited the quantitative analysis of herbal drugs in biological samples. The present work demonstrated a practicable strategy for the assay of herbs and their metabolites independent of authentic standards. A liquid chromatography–electrospray ionization–mass spectrometry (LC–ESI–MS) method for the qualitative and quantitative determination of the metabolites...
متن کاملRelative Determination Approach to the Metabolites of Protoberberine Alkaloids in Rat Urine by Liquid Chromatography Tandem Mass Spectrometry for the Comparative Studies on Rhizome coptidis and Zuojinwan Preparation
The lack of authentic standards has limited the quantitative analysis of herbal drugs in biological samples. The present work demonstrated a practicable strategy for the assay of herbs and their metabolites independent of authentic standards. A liquid chromatography–electrospray ionization–mass spectrometry (LC–ESI–MS) method for the qualitative and quantitative determination of the metabolites...
متن کاملDetermination of ochratoxin A in beer.
Because of concern about possible transmission of ochratoxin A (OA) from contaminated grain adjuncts, development of a sensitive method for its determination in beer was investigated. Solid phase extraction (SPE) on C-18 and silica gel columns in series and on an immunoaffinity column (OchraTest) were used to obtain extracts for quantitation by reverse phase liquid chromatography with fluoresce...
متن کاملComparative Pharmacokinetics of Berberine, Palmatine and Jatrorrhizine in Rat Plasma after Oral Administration of Rhizoma coptidis and Zuojinwan Using Liquid Chromatography-Tandem Mass Spectrometry
A selective and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the determination of berberine, palmatine and jatrorrhizine in rat plasma. Target compounds, together with the internal standard (metronidazole), were extracted from rat plasma samples by protein precipitation with acetonitrile-methanol (1:2, v/v). Chromatography was carried out using a ...
متن کامل