Preanalytical variability in laboratory testing: influence of the blood drawing technique.
نویسندگان
چکیده
The predominant technique used to draw blood for laboratory testing is a conventional straight needle attached to an evacuated tube system. However, alternative tools might be advantageous in exceptional circumstances. The use of butterfly devices has been traditionally discouraged for reasons of costs and due to the high risk of obtaining unsuitable samples, but there is no convincing evidence to support the latter indication. The purpose of this study was to compare results of hematological and clinical chemistry testing, after drawing blood into evacuated tubes, employing either a traditional 21-gauge straight needle or a 21-gauge butterfly device with 300-mm-grade polyvinyl chloride tubing. Blood samples and complete sets of data were successfully obtained for 30 consecutive outpatients. Of the 43 hematological and clinical chemistry parameters measured, means for paired samples collected by the two alternative drawing techniques did not differ significantly, except for serum sodium, white blood cells and platelets counts. Bland-Altman plots and limits-of-agreement analysis showed mean bias of between -7.2% and 1.7% and relative coefficients of variation ranging from 0.2% to 21.2%. The 95% agreement interval in the set of differences was acceptable and was mostly within the current analytical quality specifications for desirable bias. The rate of hemolysis in plasma was not statistically different between the two collection techniques. Taken together, the results of the present investigation suggest that, when a proper technique is used and within certain limitations, the butterfly device may be a reliable alternative to the conventional straight needle to draw blood for laboratory testing.
منابع مشابه
The Evaluation of Error Types and Turnaround Time of Preanalytical Phase in Biochemistry and Hematology Laboratories
Background& Objective: Each laboratory should determine the type of errors and turnaround time (TAT), especially in the preanalytical phase to report quality and timeliness of the test results. The current study aimed at investigating the common causes of preanalytical errors in biochemistry and hematology laboratories and evaluating the preanalytical ...
متن کاملPreanalytical conditions that affect coagulation testing, including hormonal status and therapy
Preanalytical conditions, be they due to the individual's physiologic state or to exogenous factors, can affect coagulation factors, in either a transient or a persistent manner, and need to be considered in laboratory testing. These conditions include physical and mental stress, diurnal variation, hormone levels and posture at the time of blood drawing. While testing of these factors has not b...
متن کاملPreanalytical quality improvement. In pursuit of harmony, on behalf of European Federation for Clinical Chemistry and Laboratory Medicine (EFLM) Working group for Preanalytical Phase (WG-PRE).
Laboratory diagnostics develop through different phases that span from test ordering (pre-preanalytical phase), collection of diagnostic specimens (preanalytical phase), sample analysis (analytical phase), results reporting (postanalytical phase) and interpretation (post-postanalytical phase). Although laboratory medicine seems less vulnerable than other clinical and diagnostic areas, the chanc...
متن کاملPreanalytical considerations in blood gas analysis
Blood gas testing is a commonly ordered test in hospital settings, where the results almost always have the potential to dictate an immediate or urgent response. The preanalytical steps in testing, from choosing the correct tests to ensuring the specimen is introduced into the instrument correctly, must be perfectly coordinated to ensure that the patient receives appropriate and timely therapy ...
متن کاملInfluence of hemolysis on routine clinical chemistry testing.
BACKGROUND Preanalytical factors are the main source of variation in clinical chemistry testing and among the major determinants of preanalytical variability, sample hemolysis can exert a strong influence on result reliability. Hemolytic samples are a rather common and unfavorable occurrence in laboratory practice, as they are often considered unsuitable for routine testing due to biological an...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry and laboratory medicine
دوره 43 3 شماره
صفحات -
تاریخ انتشار 2005