Analytical Interference by Contrast Agents in Biochemical Assays
نویسندگان
چکیده
Objective To provide a clinically relevant overview of the analytical interference by contrast agents (CA) in laboratory blood test measurements. Materials and Methods The effects of five CAs, gadobutrol, gadoterate meglumine, gadoxetate disodium, iodixanol, and iomeprol, were studied on the 29 most frequently performed biochemical assays. One-day-old plasma, serum, and whole blood were spiked with doses of each agent such that the gadolinium agents and the iodine agents reached concentrations of 0.5 mM and 12 mg iodine/mL, respectively. Subsequently, 12 assays were reexamined using 1/2 and 1/4 of these CA concentrations. The results were assessed statistically by a paired Student's t-test. Results Iodixanol produced a negative interference on the bicarbonate (p = 0.011), lactate dehydrogenase (p < 0.0001), and zinc (p = 0.0034) assays and a positive interference on the albumin (p = 0.0062), calcium (p < 0.0001), ionized calcium (p = 0.0086), iron (p < 0.0001), and potassium (p = 0.0003) assays. Iomeprol produced a negative interference on the bicarbonate (p = 0.0057) and magnesium (p = 0.0001) assays and a positive interference on the calcium (p < 0.0001) and potassium (p = 0.0012) assays. Gadoxetate disodium produced a negative interference on the iron (p < 0.0001) and zinc (p < 0.0001) assays and a positive interference on the sodium (p = 0.032) assay. Conclusion CAs cause analytical interference. Attention should be given to the above-mentioned analyte-CA combinations when assessing laboratory blood test results obtained after CA administration.
منابع مشابه
Use of an in vivo biotinylated single-chain antibody as capture reagent in an immunometric assay to decrease the incidence of interference from heterophilic antibodies.
BACKGROUND Heterophilic antibodies are a common source of interference in immunometric assays. We tested the hypothesis that the incidence of such interference could be decreased by use of a recombinant in vivo-biotinylated single-chain antibody (scFv) as the capture reagent. METHODS We established three assays for carcinoembryonic antigen (CEA) with the capture antibody either chemically bio...
متن کاملAnalytical determination of the chemical exchange saturation transfer (CEST) contrast in molecular magnetic resonance imaging
Magnetic resonance based on molecular imaging allows tracing contrast agents thereby facilitating early diagnosis of diseases in a non-invasive fashion that enhances the soft tissue with high spatial resolution. Recently, the exchange of protons between the contrast agent and water, known as the chemical exchange saturation transfer (CEST) effect, has been measured by applying a suitable pulse ...
متن کامل[Interferences by a monoclonal IgM in biochemical analyses: detection and recommendations].
We present a case of analytical interference on three parameters (lactate dehydrogenase, uric acid and alkalin phosphatase), caused by a monoclonal IgM, evidenced in a patient with Waldenström disease. Mechanism of interference was probably related to the formation of complexes between paraprotein and lithium heparin, which result in precipitation during clinical chemistry assays, inducing a bi...
متن کاملComparison between Iodixanol and Iohexol for Cervical Myelography in Cat
Objective- To evaluate and compare the radiographic efficacy and safety of a non-ionic dimeric and isotonic iodinated contrast medium, iodixanol (320 mgI/ml) and a non-ionic monomer and hypertonic contrast medium, iohexol (300 mgI/ml) in feline cervical myelography. Design- Experimental study Animals- Five adult healthy cats. Procedures- Iodixanol and iohexol were injected into the cerebello...
متن کاملInterference in laboratory tests
Interference in clinical laboratory testing can create discrepancies in test results which can lead to patient harm. In clinical chemistry, interference is defined as a cause of medically significant difference in the measurand test result due to another component or property of the sample. Interference by endogenous and exogenous substances with assays for clinical analytes is a common prob...