Magnetic cell delivery for peripheral arterial disease: A theoretical framework.

نویسندگان

  • Johannes Riegler
  • Kevin D Lau
  • Ana Garcia-Prieto
  • Anthony N Price
  • Toby Richards
  • Quentin A Pankhurst
  • Mark F Lythgoe
چکیده

PURPOSE Our aim was to compare different magnet arrangements for magnetic cell delivery to human lower leg arteries and investigate the theoretical targeting efficiency under realistic flow conditions as a possible treatment after angioplasty. Additionally the potential of scaling down or translating the magnetic actuation device for preclinical studies was explored. METHODS Using finite element methods, the magnetic field distribution was calculated in 3D for the optimization of magnet arrangements. Computational fluid dynamics simulations were performed for the human posterior tibial artery with the geometry and boundary condition data derived from magnetic resonance imaging (MRI) studies. These simulations were used to trace the trajectories of cells for an optimized magnet arrangement. Additionally the behavior of cells close to the vessel wall was investigated using a fluid-structure interaction model. RESULTS The optimal magnet for the lower leg arteries was a Halbach cylinder k3 variety (12 elements with 900 rotation steps for the magnetization orientation). With this magnet, numerical simulations predict a targeting efficiency of 6.25% could be achieved in the posterior tibial artery for cells containing 150 pg iron. Similar simulations, which were scaled down to rabbit dimensions while keeping the forces acting on a cell constant, lead to similar predicted targeting efficiencies. Fluid dynamic and fluid-structure interaction simulations predict that magnetically labeled cells within a 0.5% radii distance to the vessel wall would be attracted and remain at the wall under physiological flow conditions. CONCLUSIONS First pass capture of magnetically labeled cells under pulsatile flow conditions in human lower leg arteries leads to low targeting efficiencies. However, this can be increased to almost 100% by stopping the blood flow for 5 min. A magnetic actuation device can be designed for animal models that generate magnetic forces achievable for cells in human leg arteries.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

CT and quantitative 19F MRI tracking of encapsulated mesenchymal stem cells in a peripheral arterial disease rabbit model

Background Nearly 12% of Americans suffer from peripheral arterial disease (PAD) and many are not eligible for conventional angioplasty or surgical bypass. Microencapsulated stem cell (SC) therapy offers a novel means to transplant allogeneic SCs to avoid immunorejection and enable image tracking. However, quantitative evaluation of capsule fate is elusive. Here we explore c-arm CT and 19F-MRI ...

متن کامل

Design of the optimal magnetic field in application of functionalized CNT-based drug delivery toward the cell membrane: Computational Analysis

Recently, Carbon Nano (CN) structures are widely used in medical applications, especially the detection and treatment of cancer disease. Among various types of CNs, Carbone Nano Tubes (CNTs) attracted many researchers' attention to consider them toward clinical application. Regarding the intrinsic structure of CNTs, they can be used widely in drug delivery applications. Functionalized CNTs and ...

متن کامل

Surgical infrainguinal revascularization for peripheral arterial disease: factors affecting patency rate

Background: Peripheral arterial disease is a source of morbidity and mortality. Surgical vascular reconstruction is a treatment option but probability of failure and complications are important concerns. In this study, we evaluated outcome of surgical infrainguinal reconstruction and factors affecting graft patency for a period of one year. Methods: In this cohort study, 85 consecutive patie...

متن کامل

Prevalence of Peripheral Arterial Disease in Diabetic Patients

Objective: Peripheral Arterial Disease (PAD) is a state characterized by atherosclerotic occlusive disease of lower extremities. Diabetes is the main risk factor for PAD. Material and Methods: To assess the prevalence of PAD, a cross sectional study was performed on 352 diabetic patients who referred to Yazd diabetes research center from 2007 to 2010. Vascular assessment was done by measuring ...

متن کامل

An Efficient Framework for Accurate Arterial Input Selection in DSC-MRI of Glioma Brain Tumors

Introduction: Automatic arterial input function (AIF) selection has an essential role in quantification of cerebral perfusion parameters. The purpose of this study is to develop an optimal automatic method for AIF determination in dynamic susceptibility contrast magnetic resonance imaging (DSC-MRI) of glioma brain tumors by using a new preprocessing method.Material and Methods: For this study, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Medical physics

دوره 38 7  شماره 

صفحات  -

تاریخ انتشار 2011